S1 pediculoiliac screw fixation in instabilities of the sacroiliac complex:: Biomechanical study and report of two cases

被引:69
作者
Sar, C [1 ]
Kilicoglu, Ö [1 ]
机构
[1] Istanbul Univ, Istanbul Fac Med, Dept Orthopaed & Traumatol, TR-34390 Istanbul, Turkey
关键词
pelvis; fracture; sacroiliac complex injury; internal fixation; mechanical testing;
D O I
10.1097/00005131-200304000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: A new technique for posterior sacroiliac fixation is described and compared with conventional techniques. Patients/Material and Methods: A patient with sacral alar fracture (zone 1) and another one with sacroiliac joint instability due to tuberculous infection underwent fixation using screws placed in the S1 pedicle and the iliac bone. Vertical stability of the new. technique also was investigated using polyurethane pelvic bone analogs and compared with anterior double plating (group P) and iliosacral screw fixation (group ISS) techniques. Results: Healing was obtained and reduction was maintained in both patients on the final follow-up examination at 2 scars postoperatively. Vertical loading tests revealed that failure loads within the first 10 mm of displacement of the new pediculoiliac scream fixation technique (group PIS) was higher than plating, (P = 0.03) and lower than ISS techniques (P = 0.002). Ultimate failure load of the PIS technique was slightly higher than plating (P = 0.277) and lower than ISS techniques (P = 0.003). With the addition of an iliosacral screw to the pediculoiliac screw construction (PIS+ISS), the PIS technique became more stable in early (P = 0.110) and ultimate failure loads (P = 0.003). Conclusions: Pediculoiliac screw fixation for sacroiliac joint disruptions and zone 1 sacrum fractures using iliac and S1 pedicle screws is a new and effective alternative for obtaining and maintaining anatomic reduction.
引用
收藏
页码:262 / 270
页数:9
相关论文
共 24 条
[1]
Reduction and fixation of sacroiliac joint dislocation by the combined use of S1 pedicle screws and the Galveston technique [J].
Abumi, K ;
Saita, M ;
Iida, T ;
Kaneda, K .
SPINE, 2000, 25 (15) :1977-1983
[2]
Albert M J, 1993, J Orthop Trauma, V7, P226, DOI 10.1097/00005131-199306000-00005
[3]
THE GALVESTON TECHNIQUE FOR L-ROD INSTRUMENTATION OF THE SCOLIOTIC SPINE [J].
ALLEN, BL ;
FERGUSON, RL .
SPINE, 1982, 7 (03) :276-284
[4]
Beaupre G S, 1992, J Orthop Trauma, V6, P294, DOI 10.1097/00005131-199209000-00005
[5]
Traumatic spondylopelvic dissociation - A case report and literature review [J].
Bents, RT ;
France, JC ;
Glover, JM ;
Kaylor, KL .
SPINE, 1996, 21 (15) :1814-1819
[6]
INFLUENCE OF BONE-MINERAL DENSITY ON THE FIXATION OF THORACOLUMBAR IMPLANTS - A COMPARATIVE-STUDY OF TRANSPEDICULAR SCREWS, LAMINAR HOOKS, AND SPINOUS PROCESS WIRES [J].
COE, JD ;
WARDEN, KE ;
HERZIG, MA ;
MCAFEE, PC .
SPINE, 1990, 15 (09) :902-907
[7]
Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures [J].
Comstock, CP ;
vanderMeulen, MCH ;
Goodman, SB .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (08) :517-522
[8]
KACH K, 1994, UNFALLCHIRURG, V97, P28
[9]
Biomechanics of the Gazi type pelvis external skeletal fixator [J].
Korkusuz, F ;
Kaymak, O ;
Citipitioglu, E ;
Akkas, N .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (05) :401-409
[10]
Korovessis P, 2000, ORTHOPEDICS, V23, P323