Optimisation of a heterogeneous non-competitive flow immunoassay comparing fluorescein, peroxidase and alkaline phosphatase as labels

被引:18
作者
Lindgren, A
Emnéus, J
Marko-Varga, G
Irth, H
Oosterkamp, A
Eremin, SA
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[2] Astro Draco AB, Dept Bioanalyt Chem, Preclin Res & Dev, S-22100 Lund, Sweden
[3] Leiden Univ, Leiden Amsterdam Ctr Drug Res, Div Analyt Chem, NL-2300 RA Leiden, Netherlands
[4] Moscow MV Lomonosov State Univ, Dept Chem, Div Chem Enzymol, Moscow 000958, Russia
关键词
heterogeneous non-competitive flow immunoassay; alkaline phosphatase; peroxidase; fluorescein; digoxin; digoxigenin; fluorescence;
D O I
10.1016/S0022-1759(97)00169-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Off- and on-line strategies for a non-competitive heterogeneous flow immunoassay were developed comparing three different labels. The samples, containing the model compounds digoxin or digoxigenin, were either pre-incubated off-line or on-line in a mixing coil with excess of labelled anti-digoxigenin Fab-fragments. The excess of Fab-fragments was then separated from the digoxin bound Fab-fragments by passing the sample through a column with immobilised digoxin. The off-line immunochemical detection system is suitable for sensitive high through-put screening of the analytes, whereas the on-line system is more suitable for coupling as a post-column detection unit to liquid chromatography. The digoxin and digoxigenin content in the sample were quantified using fluorescein (F) and enzyme (peroxidase (POD), alkaline phosphatase (AP)) labelled Fab-fragments. The fluorescein label was directly measured with the fluorescence detector, whereas a fluorescent enzyme product was measured in the two enzyme based systems, using 3-(p-hydroxyphenyl)-propionic acid (HPPA) and hydrogen peroxide for POD and, and 4-methylumbelliferyl phosphate (4-MUP) for AP. The highest sensitivity and lowest limit of detection (LOD) was obtained with the Fab-POD system with LODs for digoxin and digoxigenin in the off-and on-line configurations of 0.025 and 0.01 nM, respectively. The sample through-put for the off and on-line systems were 43 and 32 samples per hour, respectively. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:33 / 42
页数:10
相关论文
共 22 条
[1]   FLOW-INJECTION ENZYME-IMMUNOASSAY OF HAPTENS WITH ENHANCED CHEMILUMINESCENCE DETECTION [J].
AREFYEV, AA ;
VLASENKO, SB ;
EREMIN, SA ;
OSIPOV, AP ;
EGOROV, AM .
ANALYTICA CHIMICA ACTA, 1990, 237 (02) :285-289
[2]   Flow injection enzyme immunoassay of atrazine herbicide in water [J].
Bjarnason, B ;
Bousios, N ;
Eremin, SA ;
Johansson, G .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :111-120
[3]   KINETIC CHROMATOGRAPHIC SEQUENTIAL ADDITION IMMUNOASSAYS USING PROTEIN-A AFFINITY-CHROMATOGRAPHY [J].
CASSIDY, SA ;
JANIS, LJ ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1973-1977
[4]  
DFRUTOS M, 1995, TRENDS ANAL CHEM, V14, P133
[5]   BIOSPECIFIC DETECTION IN LIQUID-CHROMATOGRAPHY [J].
EMNEUS, J ;
MARKOVARGA, G .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :191-243
[6]   NONCOMPETITIVE FLOW-INJECTION IMMUNOASSAY FOR A HAPTEN, ALPHA-(DIFLUOROMETHYL)ORNITHINE [J].
GUNARATNA, PC ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1152-1157
[7]   ONLINE IMMUNOCHEMICAL DETECTION IN LIQUID-CHROMATOGRAPHY USING FLUORESCEIN-LABELED ANTIBODIES [J].
IRTH, H ;
OOSTERKAMP, AJ ;
VANDERWELLE, W ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2) :65-72
[8]   STRATEGIES FOR ONLINE COUPLING OF IMMUNOASSAYS TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IRTH, H ;
OOSTERKAMP, AJ ;
TJADEN, UR ;
VANDERGREEF, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :355-361
[9]   HETEROGENEOUS FLUORESCENCE IMMUNOASSAYS USING FLOW-INJECTION ANALYSIS WITH PROTEIN-G SOLID-PHASE REACTORS [J].
KHOKHAR, MY ;
MILLER, JN ;
SEARE, NJ .
ANALYTICA CHIMICA ACTA, 1994, 290 (1-2) :154-158
[10]   DETERMINATION OF DRUGS IN BIOSAMPLES AT PICOMOLAR CONCENTRATIONS USING COMPETITIVE ELISA WITH ELECTROCHEMICAL DETECTION - APPLICATION TO STEROIDS [J].
KRONKVIST, K ;
LOVGREN, U ;
EDHOLM, LE ;
JOHANSSON, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (06) :459-467