Blood contamination of the aerosols produced by in vivo use of ultrasonic scalers

被引:43
作者
Barnes, JB [1 ]
Harrel, SK [1 ]
Rivera-Hidalgo, F [1 ]
机构
[1] Texas A&M Univ Syst, Baylor Coll Dent, Dept Periodont, Dallas, TX USA
关键词
air pollution prevention and control; aerosols; disease transmission; blood-borne pathogens; infection control; ultrasonics instrumentation; ultrasonics methods;
D O I
10.1902/jop.1998.69.4.434
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
DISEASE TRANSMISSION AND BARRIER TECHNIQUES during dental treatment have been areas of recent concern in dentistry. Ultrasonic scalers are known to produce aerosols, and these aerosols are often produced from areas of significant disease activity, including bleeding. This study was performed to determine if these aerosols contain blood from the gingival sulcus. Forty areas consisting of two contiguous periodontally involved teeth (probing depth of at least 5 mm on one site of each tooth) were scaled subgingivally with an ultrasonic scaler for 30 seconds. A high volume evacuator (HVE) tip was positioned 3 to 5 cm away from the operating site and utilized to capture the aerosols produced. The water remaining in and on the HVE tube was tested for occult blood by the guiac resin method. Gingival index, mean probing depth, presence of bleeding with scaling, and presence of visible blood in the HVE tip were recorded. All 40 test sites showed a positive result for blood in the captured aerosols despite the wide variation in the measured parameters. It may be concluded that subgingival scaling on periodontally involved teeth with ultrasonic scalers would be expected to produce aerosols containing blood.
引用
收藏
页码:434 / 438
页数:5
相关论文
共 20 条
[11]  
LOE HARALD, 1963, ACTA ODONTOL SCAND, V21, P533, DOI 10.3109/00016356309011240
[12]   STUDIES ON DENTAL AEROBIOLOGY .I. BACTERIAL AEROSOLS GENERATED DURING DENTAL PROCEDURES [J].
MICIK, RE ;
MILLER, RL ;
MAZZARELLA, MA ;
RYGE, G .
JOURNAL OF DENTAL RESEARCH, 1969, 48 (01) :49-+
[13]  
MILLER RL, 1995, AM IND HYG ASSOC J, V56, P670, DOI 10.1202/0002-8894(1995)056<0670:COBAGB>2.0.CO
[14]  
2
[15]  
MILLER RL, 1978, DENT CLIN N AM, V22, P453
[16]   REDUCTION OF MICROBIAL-CONTAMINATION FROM ULTRASONIC SCALERS [J].
MUIR, KF ;
ROSS, PW ;
MACPHEE, IT ;
HOLBROOK, WP ;
KOWOLIK, MJ .
BRITISH DENTAL JOURNAL, 1978, 145 (03) :76-78
[17]   AIR SAMPLING FOR HEPATITIS-B SURFACE-ANTIGEN IN A DENTAL OPERATORY [J].
PETERSEN, NJ ;
BOND, WW ;
FAVERO, MS .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1979, 99 (03) :465-467
[18]   EFFICACY OF FACE MASKS IN PREVENTING INHALATION OF AIRBORNE CONTAMINANTS [J].
PIPPIN, DJ ;
VERDERAME, RA ;
WEBER, KK .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (04) :319-323
[19]   LAMINAR AIR PURGE OF MICROORGANISMS IN DENTAL AEROSOLS - PROPHYLACTIC PROCEDURES WITH ULTRASONIC SCALER [J].
WILLIAMS, GH ;
POLLOK, NL ;
SHAY, DE ;
BARR, CE .
JOURNAL OF DENTAL RESEARCH, 1970, 49 (06) :1498-&
[20]  
1993, MORBIDITY MORTALITY, V5, P1