Separation/preconcentration of trace heavy metals in urine, sediment and dialysis concentrates by coprecipitation with samarium hydroxide for atomic absorption spectrometry

被引:122
作者
Saracoglu, S
Soylak, M [1 ]
Elci, L
机构
[1] Erciyes Univ, Dept Chem, Fac Art & Sci, TR-38039 Kayseri, Turkey
[2] Pamukkale Univ, Dept Chem, Fac Art & Sci, TR-20020 Denizli, Turkey
关键词
coprecipitation; samarium hydroxide; urine; dialysis concentrate;
D O I
10.1016/S0039-9140(02)00501-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multi-element determination of trace elements in urine and dialysis solutions by atomic absorption spectrometry has been investigated. Coprecipitation with samarium hydroxide was used for preconcentration of trace elements and elimination of matrix elements. To 10 ml of each sample was added 500 mul of 2 mg ml(-1) samarium solutions; the pH was then adjusted to 12.2 in order to collect trace heavy metals on samarium hydroxide. The precipitate was separated by centrifugation and dissolved in 1 ml of 1 mol l(-1) HNO3. Coprecipitation parameters and matrix effects are discussed. The precision, based on replicate analysis, is around 5% for the analytes, and recovery is quantitative, based on analysis of spiked samples and solutions including matrix components. The time required for the coprecipitation and determination was about 30 min. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 31 条
[1]   Determination of copper and cadmium by atomic absorption spectrometry with electrochemical and sorption preconcentration [J].
Abdullin, IF ;
Turova, EN ;
Budnikov, GK .
JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 55 (06) :567-569
[2]  
Aydemir T, 1996, CHEM ANAL-WARSAW, V41, P829
[3]   Evaluation of several gas chromatographic stationary phases for the solid-phase extraction of trace amounts of copper in aqueous samples [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF ;
He, B .
ANALYTICAL SCIENCES, 2002, 18 (06) :705-707
[4]   Preconcentration of trace heavy metals in water by coprecipitation with magnesium oxinate for electrothermal atomic absorption spectrometry [J].
Chen, ZS ;
Hiraide, M ;
Kawaguchi, H .
MIKROCHIMICA ACTA, 1996, 124 (1-2) :27-34
[5]  
CHEN ZS, 1993, BUNSEKI KAGAKU, V42, P759
[6]   Determination of some trace metals in water and sediment samples by flame atomic absorption spectrometry after coprecipitation with cerium (IV) hydroxide [J].
Divrikli, Ü ;
Elçi, L .
ANALYTICA CHIMICA ACTA, 2002, 452 (02) :231-235
[7]   Applying magnesium hydroxide coprecipitation method for trace analysis to dialysis concentrate [J].
Elci, L ;
Saracoglu, S .
TALANTA, 1998, 46 (06) :1305-1310
[8]   Application of Doehlert matrix and factorial designs in optimization of experimental variables associated with preconcentration and determination of molybdenum in sea-water by inductively coupled plasma optical emission spectrometry [J].
Ferreira, SLC ;
dos Santos, HC ;
Fernandes, MS ;
de Carvalho, MS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (02) :115-120
[9]  
Hansen EH, 1998, LAB ROBOTICS AUTOMAT, V10, P347, DOI 10.1002/(SICI)1098-2728(1998)10:6<347::AID-LRA5>3.0.CO
[10]  
2-7