SYBR Green I;
real-time PCR;
Japanese encephalitis virus;
D O I:
10.1016/j.jviromet.2007.02.011
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
One-step SYBR Green I-based real-time RT-PCR assay for rapid detection as well as quantitation of Japanese encephalitis virus (JEV) in acute-phase patient CSF samples by targeting the NS3 gene was developed. The assay developed in this study was found to be more sensitive as compared to conventional RT-PCR. The specificity of the reported assay system was established through melting curve analysis as well as by cross-reactivity studies with related members of Flavivirus. The applicability of Real-time PCR assay for clinical diagnosis was validated with 32 suspected acute-phase CSF samples of Gorakhpur epidemic, India, 2005. The improved sensitivity of real-time RT-PCR was reflected by picking up 10 additional samples with low copy number of template in comparison to conventional RT-PCR. The quantitation of the viral load in acute-phase CSF samples was done using a standard curve obtained by plotting cycle threshold (C-t) values versus copy numbers of the RNA template. This is the first report on the application of real-time RT-PCR for detection as well as quantitation of JEV from patient CSF samples. These findings demonstrate the potential clinical application of the reported assay as a sensitive diagnostic test for rapid and real-time detection and quantitation of JEV in acute-phase clinical samples. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 30 条
[1]
Banerjee K, 1996, INDIAN J MED RES, V103, P177