pH dependence of the hydrophobicity of β-blocker amine compounds measured by counter-current chromatography

被引:38
作者
Carda-Broch, S [1 ]
Berthod, A [1 ]
机构
[1] Univ Lyon 1, CNRS, Sci Analyt Lab, F-69622 Villeurbanne, France
关键词
counter-current chromatography; partition coefficients; hydrophobicity; octanol-water partition coefficients; beta-blockers; ionizable compounds;
D O I
10.1016/S0021-9673(03)00534-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The octanol-water partition coefficients (P-oct) of 17 antiadrenergic beta-blocker compounds were determined by countercurrent chromatography (CCC). Since CCC uses a biphasic liquid system, the octanol-water liquid system was used with essentially an octanol stationary phase and aqueous buffer mobile phase. The P-oct coefficients were obtained directly without any extrapolation. The measured P-oct values were in the 0.0015-4070 range ( -2.8 < log P-oct < 3.6). Since the beta-blocking agents are ionizable compounds, the P-oct values obtained were strongly dependent on the aqueous-phase pH. The apparent P-oct coefficients of the beta-blockers were determined at three different pH values (similar to3, 7 and 11) using 0.01 M ammonium phosphate buffers saturated with octanol. A model allowed us to obtain the molecular and ionic P-oct value using the solute pK(a) with these three experimental octanol-water coefficients. Often, the P-oct coefficients of the molecular forms obtained with the CCC method differ significantly from computed literature values and/or experimental values obtained by extrapolation. Relationships between biological properties and hydrophobicity were also examined. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:55 / 66
页数:12
相关论文
共 34 条
[21]   Chromatography on cells and biomolecular assemblies [J].
Lundqvist, A ;
Lundahl, P .
JOURNAL OF CHROMATOGRAPHY B, 1997, 699 (1-2) :209-220
[22]  
MANDAVA NB, 1989, CHROMATOGRAPHIC SCI, V44
[23]   DIRECT MEASUREMENT OF OCTANOL-WATER PARTITION-COEFFICIENTS USING CENTRIFUGAL PARTITION CHROMATOGRAPHY WITH A BACK-FLUSHING TECHNIQUE [J].
MENGES, RA ;
BERTRAND, GL ;
ARMSTRONG, DW .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (15) :3061-3077
[24]   Micellar liquid chromatography for prediction of drug transport [J].
Molero-Monfort, M ;
Martín-Biosca, Y ;
Sagrado, S ;
Villanueva-Camañas, RM ;
Medina-Hernández, MJ .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :1-11
[25]   Immobilized-artificial-membrane chromatography: Measurements of membrane partition coefficient and predicting drug membrane permeability [J].
Ong, SW ;
Liu, HL ;
Pidgeon, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :113-128
[26]   Simultaneous determination of eight β-blockers by gradient high-performance liquid chromatography with combined ultraviolet and fluorescence detection in corneal permeability studies in vitro [J].
Ranta, VP ;
Toropainen, E ;
Talvitie, A ;
Auriola, S ;
Urtti, A .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 772 (01) :81-87
[27]   Liquid chromatographic procedure for the evaluation of beta-blockers in pharmaceuticals using hybrid micellar mobile phases [J].
RapadoMartinez, I ;
GarciaAlvarezCoque, MC ;
VillanuevaCamanas, RM .
JOURNAL OF CHROMATOGRAPHY A, 1997, 765 (02) :221-231
[28]  
REYNOLD JEF, 1989, MARTINDALE EXTRA PHA
[29]  
Scribiane A, 1980, PHARM ANTIHYPERTENSI, P179
[30]  
SHOENWALD RD, 1983, J PHARM SCI, V72, P1266