Localized eddy current compensation using quantitative field mapping

被引:57
作者
Terpstra, M [1 ]
Andersen, PM [1 ]
Gruetter, R [1 ]
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55112 USA
关键词
eddy currents; rat brain; in vivo; H-1; NMR;
D O I
10.1006/jmre.1997.1353
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Eddy current effects induced by switched gradients in proximal conducting structures are traditionally reduced by applying pre-emphasis currents whose amplitudes and decay characteristics must be set to offset the eddy current fields. We present an expeditious, localized, and quantitative method for mapping and adjusting the parameters for eddy current compensation. Mapping is based on analysis of projections as used in the fast automatic shimming technique by mapping along projections (FASTMAP). Adjustment methods are demonstrated in high-field horizontal bore systems. The proposed localized eddy current mapping technique may also be used for localized measurements in situations where asymmetric conducting structures may cause nonlinear eddy current fields, such as in interventional MRI and open magnet designs. (C) 1998 Academic Press.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 23 条
[1]   TEMPORAL AND SPATIAL-ANALYSIS OF FIELDS GENERATED BY EDDY CURRENTS IN SUPERCONDUCTING MAGNETS - OPTIMIZATION OF CORRECTIONS AND QUANTITATIVE CHARACTERIZATION OF MAGNET GRADIENT SYSTEMS [J].
BOESCH, C ;
GRUETTER, R ;
MARTIN, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) :268-284
[2]   SCREENED COIL DESIGNS FOR NMR IMAGING IN MAGNETS WITH TRANSVERSE FIELD GEOMETRY [J].
BOWTELL, R ;
MANSFIELD, P .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (05) :431-439
[3]   A METHOD FOR MAPPING MAGNETIC-FIELDS GENERATED BY CURRENT COILS [J].
CHANKJI, J ;
LEFEVRE, JL ;
BRIGUET, A .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (12) :1014-1017
[4]   PRACTICAL ASPECTS OF SHIELDED GRADIENT-COIL DESIGN FOR LOCALIZED IN-VIVO NMR-SPECTROSCOPY AND SMALL-SCALE IMAGING [J].
ECCLES, CD ;
CROZIER, S ;
ROFFMAN, WG ;
DODDRELL, DM ;
BACK, P ;
CALLAGHAN, PT .
MAGNETIC RESONANCE IMAGING, 1994, 12 (04) :621-630
[5]   STIMULATED ECHO IMAGING [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W ;
HAASE, A .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) :81-93
[6]   A programmable eddy-current compensation system for MRI and localized spectroscopy [J].
Fry, ME ;
Pittard, S ;
Summers, IR ;
Vennart, W ;
Goldie, FTD .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02) :455-458
[7]   Observation of resolved glucose signals in H-1 NMR spectra of the human brain at 4 Tesla [J].
Gruetter, R ;
Garwood, M ;
Ugurbil, K ;
Seaquist, ER .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :1-6
[8]   AUTOMATIC, LOCALIZED INVIVO ADJUSTMENT OF ALL 1ST-ORDER AND 2ND-ORDER SHIM COILS [J].
GRUETTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :804-811
[9]  
GRUETTER R, 1997, SOC INT MAGN RES MED, P239
[10]   ANALYTICAL METHOD FOR THE COMPENSATION OF EDDY-CURRENT EFFECTS INDUCED BY PULSED MAGNETIC-FIELD GRADIENTS IN NMR SYSTEMS [J].
JEHENSON, P ;
WESTPHAL, M ;
SCHUFF, N .
JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (02) :264-278