A new liquid-phase microextraction method based on solidification of floating organic drop

被引:499
作者
Zanjani, Mohammad Reza Khalih
Yamini, Yadollah
Shariati, Shahab
Jonsson, Jan Ake
机构
[1] Tarbiat Modares Univ, Sch Sci, Dept Chem, Tehran, Iran
[2] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
liquid-phase microextraction; water analysis; gas chromatography-flame ionization detection; polycyclic aromatic hydrocarbons;
D O I
10.1016/j.aca.2006.12.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, a new and versatile liquid-phase rnicroextraction method is described. This method requires very simple and cheap apparatus and also a small amount of organic solvent. Eight microliters of 1-undecanol was delivered to the surface of solution containing analytes and solution was stirred for a desired time. Then sample vial was cooled by inserting it into an ice bath for 5 min. The solidified 1-undecanol was transferred into a suitable vial and immediately melted; then, 2 mu L of it was injected into a gas chromatograph for analysis. Some polycyclic aromatic hydrocarbons (PAHs) were used as model compounds for developing and evaluating of the method performance. Analysis was carried out by gas chromatography/flame ionization detection (GC/FID). Several factors influencing the microextraction efficiency, such as the nature and volume of organic solvent, the temperature and volume of sample solution, stirring rate and extraction time were investigated and optimized. The applicability of the technique was evaluated by determination of trace amounts of PAHs in environmental samples. Under the optimized conditions, the detection limits (LOD) of the method were in the range of 0.07-1.67 mu g L-1 and relative standard deviations (R.S.D.) for 10 mu g L-1 PAHs were < 7%. A good linearity (r(2) > 0.995) in a calibration range of 0.25-300.00 mu g L-1 was obtained. After 30 thin extraction duration, enrichment factors were in the range of 594-1940. Finally, the proposed method was applied to the determination of trace amounts of PAHs in several real water samples, and satisfactory results were resulted. Since very simple devices were used, this new technique is affordable, efficient, and convenient for extraction and determination of low concentrations of PAHs in water samples. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:286 / 293
页数:8
相关论文
共 50 条
[1]  
American Public Health Association, 1995, STAND METH EX WAT WA
[2]   Rapid analysis of pentazocine in human plasma by liquid chromatography/mass spectrometry with sonic spray ionization [J].
Arinobu, T ;
Hattori, H ;
Ishii, A ;
Kumazawa, T ;
Lee, XP ;
Kojima, S ;
Suzuki, O ;
Seno, H .
ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) :249-252
[3]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[4]   Immersed solvent microextraction and gas chromatography-mass spectrometric detection of s-triazine herbicides in aquatic media [J].
Bagheri, H ;
Khalilian, F .
ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) :81-87
[5]   Immersed solvent microextraction of phenol and chlorophenols from water samples followed by gas chromatography-mass spectrometry [J].
Bagheri, H ;
Saber, A ;
Mousavi, SR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :27-33
[6]  
BJORSETH A, 1983, HDB POLYCYCLIC AROMA, P727
[7]  
BLUMER M, 1976, SCI AM, V234, P35
[8]   POLYCYCLIC AROMATIC-HYDROCARBONS IN SOILS AND RECENT SEDIMENTS [J].
BLUMER, M ;
YOUNGBLOOD, WW .
SCIENCE, 1975, 188 (4183) :53-55
[9]  