Significant coronary artery stenosis: Comparison on per-patient and per-vessel or per-segment basis at 64-section CT angiography

被引:88
作者
Herzog, Christopher
Zwerner, Peter L.
Doll, Josh R.
Nielsen, Christopher D.
Nguyen, Shaun A.
Savino, Giancarlo
Vogl, Thomas J.
Costello, Philip
Schoepf, U. Joseph
机构
[1] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[3] Goethe Univ Frankfurt, Dept Radiol, Frankfurt, Germany
关键词
D O I
10.1148/radiol.2441060332
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively evaluate the accuracy of 64-section computed tomographic (CT) coronary angiography for assessing significant stenosis on a global and segmental level, by using conventional coronary artery angiography as the reference standard. Materials and Methods: This study was HIPAA compliant and had local institutional review board approval. Patients gave informed consent. Patients suspected of having coronary artery disease (CAD) underwent both conventional coronary catheter angiography and contrast material - enhanced retrospectively electrocardiographically gated 64- section multi - detector row CT of the coronary arteries. Two experienced observers analyzed all CT scans for signs of CAD (stenosis of 0%, <= 49%, 50% - 69%, 70% - 99%, or 100%). Diagnostic accuracy of CT coronary angiography compared with that of conventional angiography was determined on a per- segment, per-vessel, and per-patient basis. No patients, vessels, or segments were excluded from analysis. Spearman correlation, cross tables, and a X-2 test were used for statistical analysis. Results: On a per-segment basis, 92.4% ( 762 of 825) of all segments could be clearly evaluated. In 7.6% of segments, image quality was compromised either by misregistration ( 16%), motion artifacts ( 30%), or small vessel size ( 54%). Correlation coefficients for detection and grading of stenosis were r = 0.65 on a per- segment, r = 0.83 on a per-vessel, and r = 0.88 on a per-patient basis. Stenoses of 50% or greater were detected with accuracy, sensitivity, and specificity, respectively, of 96.1% ( 793 of 825), 82% ( 50 of 61), and 97.1% ( 743 of 765) on a per- segment basis, 90.9% ( 150 of 165), 89% ( 32 of 36), and 91.5% ( 118 of 129) on a per- vessel basis, and 89% ( 49 of 55), 100% ( 19 of 19), and 83% ( 30 of 36) on a per- patient basis. Conclusion: On a per-patient basis, 64-section multi-detector row CT coronary angiography enables the diagnosis of significant ( >= 50%) stenosis in CAD with an accuracy of 89%. On a per-segment and per-vessel basis, diagnostic accuracy is still impaired, primarily by limited spatial resolution. (c) RSNA, 2007.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 21 条
[1]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[2]  
*AM HEART ASS, 2001, 2002 HEART STROK STA
[3]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[4]   A TEST FOR SYMMETRY IN CONTINGENCY TABLES [J].
BOWKER, AH .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1948, 43 (244) :572-574
[5]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358
[6]   Image reconstruction and image quality evaluation for a 16-slice CT scanner [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Polacin, A ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (05) :832-845
[7]   Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system [J].
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Suess, C ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (10) :2650-2662
[8]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[9]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[10]  
FORCINITO M, 1991, J AM COLL CARDIOL, V18, P1149