A survey on high-concentration-capability headspace sampling techniques in the analysis of flavors and fragrances

被引:35
作者
Bicchi, C [1 ]
Cordero, C [1 ]
Rubiolo, P [1 ]
机构
[1] Univ Turin, Dipartimento Sci & Tecnol Farm, I-10125 Turin, Italy
关键词
D O I
10.1093/chromsci/42.8.402
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This survey critically discusses high-concentration-capacity (HCC) headspace (HS) techniques applied to sample the volatile fraction of matrices of interest in the flavors and fragrance fields. In particular, the advantages, limits, and fields of application of HS solid-phase microextraction (SPME), high-capacity HS sorptive extraction (HSSE) and HS solid-phase dynamic extraction (SPDE) are evaluated. These techniques are discussed in view of the peculiar characteristic of HCC-HS techniques, from the standpoint that these techniques are a bridge between static (S-HS) and dynamic HS (D-HS) because they are as simple, fast, easy to automate, and reliable as S-HS, yet afford analyte concentration factors comparable to those of D-HS. Moreover, the different degree of their development is a consequence of the different times in which they were introduced into the market, because the potential of HS-SPME is now well known, having been introduced approximately 12 years ago, but that of HSSE has still to be fully explored, and HS-SPDE still has to be investigated because it is very recent.
引用
收藏
页码:402 / 409
页数:8
相关论文
共 38 条
[11]  
Baltussen E., 2000, THESIS TU EINDHOVEN
[12]   Influence of fibre coating in headspace solid-phase microextraction-gas chromatographic analysis of aromatic and medicinal plants [J].
Bicchi, C ;
Drigo, S ;
Rubiolo, P .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :469-485
[13]  
Bicchi C, 2000, HRC-J HIGH RES CHROM, V23, P539, DOI [10.1002/1521-4168(20000901)23:9&lt
[14]  
539::AID-JHRC539&gt
[15]  
3.0.CO
[16]  
2-3, 10.1002/1521-4168(20000901)23:9<539::AID-JHRC539>3.0.CO
[17]  
2-3]
[18]   Automated headspace solid-phase dynamic extraction to analyse the volatile fraction of food matrices [J].
Bicchi, C ;
Cordero, C ;
Liberto, E ;
Rubiolo, P ;
Sgorbini, B .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1024 (1-2) :217-226
[19]   Headspace sorptive extraction (HSSE), stir bar sorptive extraction (SBSE), and solid phase microextraction (SPME) applied to the analysis of roasted arabica coffee and coffee brew [J].
Bicchi, C ;
Iori, C ;
Rubiolo, P ;
Sandra, P .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (03) :449-459
[20]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533