A comparison between digital images viewed on a picture archiving and communication system diagnostic workstation and on a PC-based remote viewing system by emergency physicians

被引:26
作者
Parasyn, A
Hanson, RM
Peat, JK
De Silva, M
机构
[1] Royal Alexandra Hosp Children, Dept Radiol, Parramatta, NSW 2124, Australia
[2] Univ Sydney, Sch Med, Sydney, NSW 2006, Australia
[3] Univ Sydney, Dept Pediat & Child Hlth, Sydney, NSW 2006, Australia
关键词
digitized images; picture archiving; PC images; PACS; RVS; computers; radiology;
D O I
10.1007/BF03168724
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Picture Archiving and Communication Systems (PACS) make possible the viewing of radiographic images on computer workstations located where clinical care is delivered, By the nature of their work this feature is particularly useful for emergency physicians who view radiographic studies for information and use them to explain results to patients and their families. However, the high cost of PACS diagnostic workstations with fuller functionality places limits on the number of and therefore the accessibility to workstations in the emergency department, This study was undertaken to establish how well less expensive personal computer-based workstations would work to support these needs of emergency physicians, The study compared the outcome of observations by 5 emergency physicians on a series of radiographic studies containing subtle abnormalities displayed on both a FAGS diagnostic workstation and on a PC-based workstation, The 73 digitized radiographic studies were randomly arranged on both types of workstation over four separate viewing sessions for each emergency physician. There was no statistical difference between a PACS diagnostic workstation and a PC-based workstation in this trial. The mean correct ratings were 59% on the PACS diagnostic workstations and 61% on the PC-based workstations. These findings also emphasize the need for prompt reporting by a radiologist. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 13 条
[1]   CLINICAL-EVALUATION OF A MEDICAL IMAGE MANAGEMENT-SYSTEM FOR CHEST IMAGES [J].
ARENSON, RL ;
SESHADRI, SB ;
KUNDEL, HL ;
DESIMONE, D ;
VANDERVOORDE, F ;
GEFTER, WB ;
EPSTEIN, DM ;
MILLER, WT ;
ARONCHICK, JM ;
SIMSON, MB ;
LANKEN, PN ;
KHALSA, S ;
BRIKMAN, I ;
DAVEY, M ;
BRISBON, N .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (01) :55-59
[2]  
CHINN S, 1997, INT J EPIDEMIOL, V15, P121
[3]  
COCHRANE AL, 1952, LANCET 0913, P505
[4]   DISPLAY OF CT STUDIES ON A 2-SCREEN ELECTRONIC WORKSTATION VERSUS A FILM PANEL ALTERNATOR - SENSITIVITY AND EFFICIENCY AMONG RADIOLOGISTS [J].
FOLEY, WD ;
JACOBSON, DR ;
TAYLOR, AJ ;
GOODMAN, LR ;
STEWART, ET ;
GURNEY, JW ;
STROKA, D .
RADIOLOGY, 1990, 174 (03) :769-773
[5]   HIGH-RESOLUTION COMPUTER DISPLAY OF PORTABLE, DIGITAL, CHEST RADIOGRAPHS OF ADULTS - SUITABILITY FOR PRIMARY INTERPRETATION [J].
FRANK, MS ;
JOST, RG ;
MOLINA, PL ;
ANDERSON, DJ ;
SOLOMON, SL ;
WHITMAN, RA ;
MOORE, SM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :473-477
[6]   DIGITAL RADIOGRAPHY OF THE CHEST - PROMISES AND PROBLEMS [J].
GOODMAN, LR ;
WILSON, CR ;
FOLEY, WD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) :1241-1252
[7]   DIGITAL AND CONVENTIONAL CHEST IMAGES - OBSERVER PERFORMANCE WITH FILM DIGITAL RADIOGRAPHY SYSTEM [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
RIMM, AA ;
LAWSON, TL .
RADIOLOGY, 1986, 158 (01) :27-33
[8]   DIGITAL CHEST RADIOGRAPHY - EFFECT ON DIAGNOSTIC-ACCURACY OF HARD COPY, CONVENTIONAL VIDEO, AND REVERSED GRAY SCALE VIDEO DISPLAY FORMATS [J].
MACMAHON, H ;
METZ, CE ;
DOI, K ;
KIM, T ;
GIGER, ML ;
CHAN, HP .
RADIOLOGY, 1988, 168 (03) :669-673
[9]  
MACMAHON H, 1986, RADIOLOGY, V158, P27
[10]  
RAVAZI M, 1992, AJR AM J ROENTGENOL, V158, P443