Evaluation of OS-EM vs ML-EM for 1D, 2D and fully 3D SPECT reconstruction

被引:37
作者
Kamphuis, C [1 ]
Beekman, FJ [1 ]
Viergever, MA [1 ]
机构
[1] UNIV UTRECHT HOSP,IMAGING CTR,UTRECHT,NETHERLANDS
关键词
D O I
10.1109/23.507262
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For SPECT reconstruction, iterative Maximum Likelihood Expectation Maximization (ML-EM) estimation has a huge computational burden. The objective of this paper is to compare images obtained by ML-EM and an EM algorithm acting on Ordered Subsets of projections (OS-EM). Two digital phantoms, a cylinder with two cold spots and an ellipsoid with several hot spots and one cold spot were reconstructed from 120 simulated noisy projections. 1D (delta-like point source response), 2D (single slice response) and fully 3D reconstruction were investigated. Three quantities were calculated for the evaluation, viz. contrast, normalized standard deviation and mean squared error. In the case of fully 3D reconstruction, OS-EM 60 reconstructions (i.e., using 60 ordered subsets) were very close to ML-EM reconstructions. This shows that the OS-EM algorithm is an extremely fast and efficient method to accelerate iterative SPECT reconstruction with speed-up factors of close to half the number of projections.
引用
收藏
页码:2018 / 2024
页数:7
相关论文
共 18 条
[1]   FAST SPECT SIMULATION INCLUDING OBJECT SHAPE DEPENDENT SCATTER [J].
BEEKMAN, FJ ;
VIERGEVER, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (02) :271-282
[2]   OBJECT SHAPE DEPENDENT PSF MODEL FOR SPECT IMAGING [J].
BEEKMAN, FJ ;
EIJKMAN, EGJ ;
VIERGEVER, MA ;
BORM, GF ;
SLIJPEN, ETP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (01) :31-39
[3]  
BEEKMAN FJ, 1995, INFORMATION PROCESSI, V14, P53
[4]  
BYRNE CL, UNPUB IEEE T IM P
[5]  
FORMICONI AR, 1989, PHYS MED BIOL, V34, P68
[6]   A PRACTICAL METHOD FOR INCORPORATING SCATTER IN A PROJECTOR-BACKPROJECTOR FOR ACCURATE SCATTER COMPENSATION IN SPECT [J].
FREY, EC ;
TSUI, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1107-1116
[7]   A 3D MODEL OF NONUNIFORM ATTENUATION AND DETECTOR RESPONSE FOR EFFICIENT ITERATIVE RECONSTRUCTION IN SPECT [J].
GILLAND, DR ;
JASZCZAK, RJ ;
WANG, H ;
TURKINGTON, TG ;
GREER, KL ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :547-561
[8]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[9]  
HUDSON HM, 1991, J NUCL MED, V33, P960
[10]   DISTRIBUTED 3-D ITERATIVE RECONSTRUCTION FOR QUANTITATIVE SPECT [J].
JU, ZW ;
FREY, EC ;
TSUI, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1301-1309