PEM fuel cells operated at 0% relative humidity in the temperature range of 23-120°C

被引:116
作者
Zhang, Jianlu [1 ]
Tang, Yanghua [1 ]
Song, Chaojie [1 ]
Cheng, Xuan [1 ]
Zhang, Jiujun [1 ]
Wang, Haijiang [1 ]
机构
[1] Xiamen Univ, Dept Mat Sci & Engn, State Key Lab Phys Chem Solid Surfaces, Xiamen 361005, Peoples R China
基金
中国国家自然科学基金;
关键词
PEM fuel cells; high temperature; dry reactant gas (or 0% relative humidity); external humidification;
D O I
10.1016/j.electacta.2007.02.002
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Operation of a proton exchange membrane (PEM) fuel cell without external humidification (or 0% relative humidity, abbreviated as 0% RH) of the reactant gases is highly desirable, because it can eliminate the gas humidification system and thus decrease the complexity of the PEM fuel cell system and increase the system volume power density (W/l) and weight power density (W/kg). In this investigation, a PEM fuel cell was operated in the temperature range of 23-120 degrees C, in particular in a high temperature PEM fuel cell operation range of 80-120 degrees C, with dry reactant gases, and the cell performance was examined according to varying operation parameters. An ac impedance method was used to compare the performance at 0% RH with that at 100% RH; the results suggested that the limited proton transfer process to the Pt catalysts, mainly in the inonomer within the membrane electrode assembly (MEA) could be responsible for the performance drop. It was demonstrated that operating a fuel cell using a commercially available membrane (Nafion (R) 112) is feasible under certain conditions without external humidification. However, the cell performance at 0% RH decreased with increasing operation temperature and reactant gas flow rate and decreasing operation pressure. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5095 / 5101
页数:7
相关论文
共 57 条
[11]   Quantum jumps in the PEMFC science and technology from the 1960s to the year 2000 Part II. Engineering, technology development and application aspects [J].
Costamagna, P ;
Srinivasan, S .
JOURNAL OF POWER SOURCES, 2001, 102 (1-2) :253-269
[12]   Phenomenological theory of electro-osmotic effect and water management in polymer electrolyte proton-conducting membranes [J].
Eikerling, M ;
Kharkats, YI ;
Kornyshev, AA ;
Volfkovich, YM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (08) :2684-2699
[13]  
FAITA G, 2005, Patent No. 2005060031
[14]   Effect of membrane characteristics and humidification conditions on the impedance response of polymer electrolyte fuel cells [J].
Freire, TJP ;
Gonzalez, ER .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 503 (1-2) :57-68
[15]   Water management in PEMFCs using absorbent wicks [J].
Ge, SH ;
Li, XG ;
Hsing, IM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2004, 151 (09) :B523-B528
[16]   Operation of polymer electrolyte membrane fuel cells with dry feeds: Design and operating strategies [J].
Hogarth, Warren H. J. ;
Benziger, Jay B. .
JOURNAL OF POWER SOURCES, 2006, 159 (02) :968-978
[17]   Dynamics of autohumidifed PEM fuel cell operation [J].
Hogarth, Warren H. J. ;
Benziger, Jay B. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2006, 153 (11) :A2139-A2146
[18]   Two-dimensional simulation of water transport in polymer electrolyte fuel cells [J].
Hsing, IM ;
Futerko, P .
CHEMICAL ENGINEERING SCIENCE, 2000, 55 (19) :4209-4218
[19]   Improvement of low-humidity performance of PEMFC by addition of hydrophilic SiO2 particles to catalyst layer [J].
Jung, Un Ho ;
Park, Ki Tae ;
Park, Eun Hee ;
Kim, Sung Hyun .
JOURNAL OF POWER SOURCES, 2006, 159 (01) :529-532
[20]  
KAUFMANN A, 1998, Patent No. 5776725