Fourier transform infrared imaging of human hair with a high spatial resolution without the use of a synchrotron

被引:82
作者
Chan, KLA [1 ]
Kazarian, SG [1 ]
Mavraki, A [1 ]
Williams, DR [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn & Chem Technol, London SW7 2AZ, England
关键词
attenuated total reflection infrared; ATR-IR; human hair; infrared spectroscopy; spatial resolution;
D O I
10.1366/0003702053085070
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The cross-section of a human hair has been imaged for the first time using the micro attenuated total reflection (ATR) Fourier transformed infrared (FT-IR) method in combination with a focal plane array (FPA) detector. A rigorous approach was applied to determine the spatial resolution, namely, measuring the distance over which the band absorbance changes from 95 to 5% of the maximum absorbance when passing through a sharp interface. The measured value for IR transmission was similar to16 mum, while the value obtained using ATR imaging was similar to5 mum. The enhanced spatial resolution achieved by this method allows the medulla of the hair (similar to8 mum in diameter) to be imaged clearly without the need for a synchrotron source. The spatial resolution of transmission and ATR imaging is compared, and advantages of ATR imaging are discussed.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 13 条
[1]  
Bantignies JL, 2000, J COSMET SCI, V51, P73
[2]  
Briki F, 2000, CELL MOL BIOL, V46, P1005
[3]   Resolution limits for infrared microspectroscopy explored with synchrotron radiation [J].
Carr, GL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (03) :1613-1619
[4]   Applications of attenuated total reflection infrared spectroscopic imaging to pharmaceutical formulations [J].
Chan, KLA ;
Hammond, SV ;
Kazarian, SG .
ANALYTICAL CHEMISTRY, 2003, 75 (09) :2140-2146
[5]   New opportunities in micro- and macro-attenuated total reflection infrared spectroscopic imaging: Spatial resolution and sampling versatility [J].
Chan, KLA ;
Kazarian, SG .
APPLIED SPECTROSCOPY, 2003, 57 (04) :381-389
[6]   Imaging capabilities of synchrotron infrared microspectroscopy [J].
Dumas, P ;
Jamin, N ;
Teillaud, JL ;
Miller, LM ;
Beccard, B .
FARADAY DISCUSSIONS, 2004, 126 :289-302
[7]   The use of synchrotron infrared microspectroscopy in biological and biomedical investigations [J].
Dumas, P ;
Miller, L .
VIBRATIONAL SPECTROSCOPY, 2003, 32 (01) :3-21
[8]   Combined application of imaging methods for the characterization of a polymer blend [J].
Gupper, A ;
Wilhelm, P ;
Schmied, M ;
Kazarian, SG ;
Chan, KLA ;
Reussner, J .
APPLIED SPECTROSCOPY, 2002, 56 (12) :1515-1523
[9]   Characterisation of bioactive and resorbable polylactide/Bioglass® composites by FTIR spectroscopic imaging [J].
Kazarian, SG ;
Chan, KLA ;
Maquet, V ;
Boccaccini, AR .
BIOMATERIALS, 2004, 25 (18) :3931-3938
[10]   Chemically sensitive parallel analysis of combinatorial catalyst libraries [J].
Snively, CM ;
Oskarsdottir, G ;
Lauterbach, J .
CATALYSIS TODAY, 2001, 67 (04) :357-368