Migration and wear of long-term successful Charnley total hip replacements

被引:25
作者
Ilchmann, T
Markovic, L
Joshi, A
Hardinge, K
Murphy, J
Wingstrand, H
机构
[1] Univ Lund Hosp, Dept Orthopaed, S-22185 Lund, Sweden
[2] Wrightington Hosp, Ctr Hip Surg, Wigan WN6 9EP, Lancs, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1998年 / 80B卷 / 03期
关键词
D O I
10.1302/0301-620X.80B3.8455
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We analysed in-vivo migration and wear over a long period of all-polyethylene acetabular cups which had not been affected by mechanical loosening. The selection criteria of regular radiological follow-up, good clinical outcome (Charnley score of 5 or 6), continued walking without crutches and no radiological signs of loosening of the acetabular cups were fulfilled by 25 Charnley total hip arthroplasties. Mean migration, measured by the Nunn method, was 0.6 mm in the medial and 0.2 mm in the cranial direction. The mean yearly rate of wear was 0.05 mm and 0.04 mm, with six and two cups having no detectable wear, as measured by the Livermore and Charnley-Cupic methods, respectively. The maximal detected wear was 3.7 mm, There were no changes in the rate of wear with time. Computerised Ein Bild Rontgen Analyse (single-image radiological analysis) measurements of 20 hips indicated plastic deformation of the cups. We conclude that long-term successful cups do not migrate and have a very low rate of wear which was not affected by ageing of the polyethylene. There was no evidence that polyethylene wear alone caused mechanical loosening of the cup but high rates of wear seem to have an adverse prognostic value in terms of the long-term survival of the prosthesis.
引用
收藏
页码:377 / 381
页数:5
相关论文
共 25 条
[1]
[Anonymous], CLIN ORTHOPAEDICS
[2]
[Anonymous], 1992, SOCIOLOGICA, V7
[3]
LOCALIZED ENDOSTEAL BONE LYSIS IN RELATION TO THE FEMORAL COMPONENTS OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
ANTHONY, PP ;
GIE, GA ;
HOWIE, CR ;
LING, RSM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :971-979
[4]
Charnley J, 1973, CLIN ORTHOP RELAT R, V95, P9
[5]
CHARNLEY L, 1979, LOW FRICTION ARTHROP, P246
[6]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]
GOODMAN SB, 1988, CLIN ORTHOP RELAT R, V232, P255
[8]
MEASUREMENT ACCURACY IN ACETABULAR CUP WEAR - 3 RETROSPECTIVE METHODS COMPARED WITH ROENTGEN STEREOPHOTOGRAMMETRY [J].
ILCHMANN, T ;
MJOBERG, B ;
WINGSTRAND, H .
JOURNAL OF ARTHROPLASTY, 1995, 10 (05) :636-642
[9]
ACCURACY OF THE NUNN METHOD IN MEASURING ACETABULAR CUP MIGRATION [J].
ILCHMANN, T ;
FREEMAN, MAR ;
MJOBERG, B .
UPSALA JOURNAL OF MEDICAL SCIENCES, 1992, 97 (01) :67-68
[10]
SURFACE DAMAGE TO COBALT-CHROME FEMORAL-HEAD PROSTHESES [J].
JASTY, M ;
BRAGDON, CR ;
LEE, K ;
HANSON, A ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :73-77