Tomographic mammography using a limited number of low-dose cone-beam projection images

被引:271
作者
Wu, T [1 ]
Stewart, A
Stanton, M
McCauley, T
Phillips, W
Kopans, DB
Moore, RH
Eberhard, JW
Opsahl-Ong, B
Niklason, L
Williams, MB
机构
[1] Brandeis Univ, Rosenstiel Basic Med Sci Res Ctr, Waltham, MA 02454 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
[3] Gen Elect Global Res, Niskayuna, NY 12309 USA
[4] Univ Virginia, Charlottesville, VA 22908 USA
关键词
digital mammography; computed tomography; low-dose imaging; tomosynthesis; cone-beam;
D O I
10.1118/1.1543934
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is described for using a limited number (typically 10-50) of low-dose radiographs to reconstruct the three-dimensional (3D) distribution of x-ray attenuation in the breast. The method uses x-ray cone-beam imaging, an electronic digital detector, and constrained nonlinear iterative computational techniques. Images are reconstructed with high resolution in two dimensions and lower resolution in the third dimension. The 3D distribution of attenuation that is projected into one image in conventional mammography can be separated into many layers (typically 30-80 1-mm-thick layers, depending on breast thickness), increasing the conspicuity of features that are often obscured by overlapping structure in a single-projection view. Schemes that record breast images at nonuniform angular increments, nonuniform image exposure, and nonuniform detector resolution are investigated in order to reduce the total x-ray exposure necessary to obtain diagnostically useful 3D reconstructions, and to improve the quality of the reconstructed images for a given exposure. The total patient radiation dose can be comparable to that used for a standard two-view mammogram. The method is illustrated with images from mastectomy specimens, a phantom, and human volunteers. The results show how image quality is affected by various data-collection protocols. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:365 / 380
页数:16
相关论文
共 37 条
[1]  
BULMER MG, 1967, PRINCIPLES STAT, P102
[2]   RECONSTRUCTION OF 3 DIMENSIONAL STRUCTURE FROM PROJECTIONS AND ITS APPLICATION TO ELECTRON MICROSCOPY [J].
CROWTHER, RA ;
DEROSIER, DJ ;
KLUG, A .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 317 (1530) :319-&
[3]   Globally convergent edge-preserving regularized reconstruction: An application to limited-angle tomography [J].
Delaney, AH ;
Bresler, Y .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1998, 7 (02) :204-221
[4]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[5]   Effect of scatter radiation on image noise in cone beam CT [J].
Endo, M ;
Tsunoo, T ;
Nakamori, N .
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 :514-521
[6]  
Fessler J. A., 2000, Handb. Med. Imaging, V2, P1, DOI DOI 10.1117/3.831079
[7]   Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction [J].
Fessler, JA ;
Ficaro, EP ;
Clinthorne, NH ;
Lange, K .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :166-175
[8]  
Frank J., 1992, ELECT TOMOGRAPHY 3 D
[9]  
FREY E, 1996, 3 DIMENSIONAL IMAGE, P177
[10]  
Golub G.H., 1989, MATRIX COMPUTATION