The development of near infrared wheat quality models by locally weighted regressions

被引:31
作者
Barton, FE
Shenk, JS
Westerhaus, MO
Funk, DB
机构
[1] ARS, USDA, Richard B Russell Agr Res Ctr, Athens, GA 30604 USA
[2] Penn State Univ, Dept Agron, University Pk, PA 16802 USA
[3] Fed Grain Inspect Serv, USDA, Frain Inspect Packers & Stockyard Adm, Tech Serv Ctr, Kansas City, MO 64153 USA
关键词
near infrared; NIR; chemometrics;
D O I
10.1255/jnirs.280
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A large data base of near infrared and protein data was used to examine the utility of a data base regression technique know as LOCAL in the ISI International software package. A total of 2203 samples of wheat from five classes with protein values by combustion analysis comprised the data base. One half of the samples came from hard red spring and hard red winter wheats, The number of samples in the individual classes ranged from 235 for Durum to 694 for hard red spring. These samples were collected over a five year period and represented wheat in commercial trade. Calibrations mere determined for each class, the entire data base as a "global" calibration, a data base regression which selected appropriate samples for a unique calibration for each sample and the standard equations of MR spectroscopy regulatory analysis. Results will be reported which show data base regression technique to be as good as specific calibrations by partial least squares regression for sub-classes of products and precise enough for use for regulatory purposes. The use of this data base regression technique over normal learning sets has other advantages, such as easier calibration update, easier transferability and the possibility to include authentication and classification as part of the model.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 1999, D460794 ASTM
[2]  
BENGERA I, 1968, ISRAEL J AGR RES, V18, P125
[3]   Transfer of near-infrared multivariate calibrations without standards [J].
Blank, TB ;
Sum, ST ;
Brown, SD ;
Monfre, SL .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2987-2995
[4]   CALIBRATION TRANSFER ACROSS NEAR-INFRARED SPECTROMETRIC INSTRUMENTS USING SHENKS ALGORITHM - EFFECTS OF DIFFERENT STANDARDIZATION SAMPLES [J].
BOUVERESSE, E ;
MASSART, DL ;
DARDENNE, P .
ANALYTICA CHIMICA ACTA, 1994, 297 (03) :405-416
[5]   Standardization of near-infrared spectrometric instruments [J].
Bouveresse, E ;
Hartmann, C ;
Massart, DL ;
Last, IR ;
Prebble, KA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :982-990
[6]  
DAVIES AMC, 1999, SPECTROSC EUR, V11, P22
[7]  
DAVIS M, 1988, ANIMAL MODELS PSYCHI, V1, P61
[8]   MULTIVARIATE CALIBRATION STANDARDIZATION [J].
DENOORD, OE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 25 (02) :85-97
[9]   THE EFFECT OF MULTIPLICATIVE SCATTER CORRECTION (MSC) AND LINEARITY IMPROVEMENT IN NIR SPECTROSCOPY [J].
ISAKSSON, T ;
NAES, T .
APPLIED SPECTROSCOPY, 1988, 42 (07) :1273-1284
[10]  
MARTEN GC, 1989, USDA HDB, V643