Needle-type glucose microbiosensor based on glucose oxidase immobilised in an overoxidised polypyrrole film (an in-vitro study)

被引:18
作者
Quinto, M
Losito, I
Palmisano, F
Zambonin, CG
机构
[1] Univ Bari, Dipartmento Chim, I-70126 Bari, Italy
[2] Univ Basilicata, Dipartimento Chim, I-85100 Potenza, Italy
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 367卷 / 08期
关键词
D O I
10.1007/s002160000489
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast response, needle-type glucose micro-biosensor has been fabricated by a one-step electrochemical immobilisation of glucose oxidase in a polypyrrole film. The sensor shows a remarkable rejection of electroactive interferences, especially paracetamol. The maximum bias observed in the worst situation never exceeded the value of 6%. The fabrication procedure delivered very reproducible devices and the sensitivity of a newly prepared biosensor was typically 650 nAmM(-1)cm(-2). The kinetic parameters, obtained from an existing model, permitted to understand the sensor behaviour.
引用
收藏
页码:692 / 696
页数:5
相关论文
共 29 条
[1]   In vivo rechargeable glucose biosensors [J].
Atanasov, P ;
Wilkins, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 36 (1-3) :435-447
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[3]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .5. MICROELECTRODES FOR THE DETECTION OF GLUCOSE BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1992, 117 (08) :1287-1292
[4]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[5]   INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM [J].
CENTONZE, D ;
GUERRIERI, A ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09) :729-733
[6]   PERMEATION OF SOLUTES THROUGH AN ELECTROPOLYMERIZED ULTRATHIN POLY-O-PHENYLENEDIAMINE FILM USED AS AN ENZYME-ENTRAPPING MEMBRANE [J].
CENTONZE, D ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
ELECTROANALYSIS, 1994, 6 (5-6) :423-429
[7]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[8]   Characterization of an electro-synthesized methoxylated polypyrrole film used as permselective barrier in amperometric biosensors by X-ray photoelectron and Fourier transform infrared spectroscopy [J].
De Benedetto, GE ;
Malitesta, C ;
Palmisano, F ;
Zambonin, PG .
ANALYTICA CHIMICA ACTA, 1999, 389 (1-3) :197-204
[9]  
FISHER U, 1987, DIABETOLOGIA, V30, P940
[10]   OPTIMIZATION OF A POLYPYRROLE GLUCOSE-OXIDASE BIOSENSOR [J].
FORTIER, G ;
BRASSARD, E ;
BELANGER, D .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (06) :473-490