In vivo rechargeable glucose biosensors

被引:2
作者
Atanasov, P [1 ]
Wilkins, E [1 ]
机构
[1] UNIV NEW MEXICO, DEPT CHEM & NUCL ENGN, SCH ENGN, ALBUQUERQUE, NM 87131 USA
基金
美国国家科学基金会;
关键词
glucose biosensor; implantable glucose sensor; glucose monitoring; in vitro; in vivo;
D O I
10.1016/S0925-4005(97)80111-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development stages and evaluation of an implantable, rechargeable, glucose sensor for continuous in vivo monitoring of glucose concentration are overviewed. The present approach makes it possible to extend the sensor's lifetime by in situ sensor refilling replacing spent immobilized enzyme with fresh enzyme. In the rechargeable biosensor the enzyme, glucose oxidase, is immobilized on dispersed carbon powder which is then held in a liquid suspension. The construction of the biosensor is such that the spent immobilized enzyme can be removed from the sensor body and fresh enzyme suspension is simultaneously injected via septa, without sensor disassembly or surgical access. The rechargeable sensor body is resistant to all of the standard procedures for sterilization including autoclaving. The sensor can be refilled with fresh enzyme material after sterilization. Rechargeable sensors based on both hydrogen peroxide and oxygen measuring principles have been under development. This biosensor, with a miniature potentiostat and signal transmitter is integrated into a small independently functioning device suitable for canine or other large animal implantation. Evaluation of the sensors and their recharging protocols in vitro and in vivo are discussed.
引用
收藏
页码:435 / 447
页数:13
相关论文
共 63 条
[1]   DEVELOPMENT OF A NEEDLE-TYPE BIOSENSOR FOR INTRAVASCULAR GLUCOSE MONITORING [J].
ABDELHAMID, I ;
ATANASOV, P ;
WILKINS, E .
ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) :45-54
[2]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[3]   BIOSENSOR FOR CONTINUOUS GLUCOSE MONITORING [J].
ATANASOV, P ;
WILKINS, E .
BIOTECHNOLOGY AND BIOENGINEERING, 1994, 43 (03) :262-266
[4]   GLUCOSE BIOSENSOR BASED ON OXYGEN-ELECTRODE .1. SILASTIC COATED POLYCARBONATE MEMBRANES FOR BIOSENSOR APPLICATION [J].
ATANASOV, P ;
WILKINS, E .
ANALYTICAL LETTERS, 1993, 26 (08) :1587-1612
[5]   GLUCOSE BIOSENSOR BASED ON OXYGEN-ELECTRODE .2. LONG-TERM OPERATIONAL STABILITY OF THE RECHARGEABLE GLUCOSE BIOSENSOR [J].
ATANASOV, P ;
WILKINS, E .
ANALYTICAL LETTERS, 1993, 26 (10) :2079-2094
[6]  
ATANASOV P, 1996, IN PRESS MED ENG PHY, V18
[7]   Integrated sensor-telemetry system for in vivo glucose monitoring [J].
Black, J ;
Wilkins, M ;
Atanasov, P ;
Wilkins, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 31 (03) :147-153
[8]  
Buchwald H, 1992, ASAIO J, V38, P772, DOI 10.1097/00002480-199210000-00005
[9]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[10]   BIOCATALYTIC OXIDATION OF GLUCOSE ON THE CONDUCTIVE CHARGE-TRANSFER COMPLEXES [J].
CENAS, NK ;
KULYS, JJ .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1981, 8 (01) :103-113