Orbital floor reconstruction with flexible Ethisorb patches: A retrospective long-term follow-up study

被引:69
作者
Jank, S
Emshoff, R
Schuchter, B
Strobl, H
Brandlmaier, I
Norer, B
机构
[1] Univ Innsbruck, Dept Oral & Maxillofacial Surg, A-6020 Innsbruck, Austria
[2] Univ Innsbruck, Dept Ophthalmol, A-6020 Innsbruck, Austria
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2003年 / 95卷 / 01期
关键词
D O I
10.1067/moe.2003.11
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Objective. The purpose of the study was to investigate whether a flexible, biodegradable material (Ethisorb) shows better long-term results with regard to diplopia, bulbus motility, and exophthalmos/enophthalmos compared to the use of lyophilized dura-patches and polydioxanone (PDS) foils. Methods. During a period of 6 years 435 patients with an orbital fracture were investigated retrospectively. Inclusion criteria were patients with fractures of the orbital floor with a maximum size of 2 x 2 cm. Bulbus motility, exophthalmos, enophthalmos, and diplopia were investigated during a period of 2 years. Results. One hundred twenty orbital floors were reconstructed by lyophilized dura-patches, 81 by PDS, and 136 by Ethisorb. An exploration without an implantation was performed in 91 patients. The long-term investigation 12 to 15 months after surgery showed an exophthalmos and enophthalmos incidence of 1%, whereas a reduced bulbus motility and diplopia were found in 5% and 4%, respectively. Fifteen to 24 months after surgery 2% of the patients had an exophthalmos and 1% had an enophthalmos. A reduction of bulbus motility was found in 4% of the patients, and diplopia was found in 3%. The use of Ethisorb resulted in a significantly lower incidence of exophthalmos 3 months after surgery compared to PDS. Conclusion. The low rate of acquired bulbus motility demonstrates acceptable results in using Ethisorb in the floor of the orbit.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 33 条
[1]
[Anonymous], DTSCH Z MUND KIEFER
[2]
Biocompatibility evaluation of dura mater substitutes in an animal model [J].
Barbolt, TA ;
Odin, M ;
Léger, M ;
Kangas, L ;
Holste, J ;
Liu, SH .
NEUROLOGICAL RESEARCH, 2001, 23 (08) :813-820
[3]
BLOW-OUT FRACTURE OF THE ORBIT - DIAGNOSTIC AND THERAPEUTIC CONSIDERATIONS, AND RESULTS IN 90 PATIENTS TREATED [J].
BARTKOWSKI, SB ;
KRZYSTKOWA, KM .
JOURNAL OF MAXILLOFACIAL SURGERY, 1982, 10 (03) :155-164
[4]
LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[5]
Effectiveness of a new perforated 0.15mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor [J].
Dietz, A ;
Ziegler, CM ;
Dacho, A ;
Althof, F ;
Conradt, C ;
Kolling, G ;
von Boehmer, H ;
Steffen, H .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2001, 29 (02) :82-88
[6]
[7]
Tightness of duraplasty in rabbits: A comparative study [J].
Filippi, R ;
Derdilopoulos, A ;
Heimann, A ;
Krummenauer, F ;
Perneczky, A ;
Kempski, O .
NEUROSURGERY, 2000, 46 (06) :1470-1476
[8]
Long-term sequelae after surgery for orbital floor fractures [J].
Folkestad, L ;
Westin, T .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1999, 120 (06) :914-921
[9]
LONG-TERM RESULTS AFTER PRIMARY RESTORATION OF THE ORBITAL FLOOR [J].
FRIESENECKER, J ;
DAMMER, R ;
MORITZ, M ;
NIEDERDELLMANN, H .
JOURNAL OF CRANIO-MAXILLO-FACIAL SURGERY, 1995, 23 (01) :31-33
[10]
Reconstruction of orbital fractures with dehydrated human dura mater [J].
Guerra, MFM ;
Pérez, JS ;
Rodriguez-Campo, FJ ;
Gías, LN .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (12) :1361-1366