A passive planar micromixer with obstructions for mixing at low Reynolds numbers

被引:252
作者
Bhagat, Ali Asgar S. [1 ]
Peterson, Erik T. K. [1 ]
Papautsky, Ian [1 ]
机构
[1] Univ Cincinnati, Dept Elect & Comp Engn, Cincinnati, OH 45221 USA
关键词
D O I
10.1088/0960-1317/17/5/023
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Passive mixers rely on the channel geometry to mix fluids. However, many previously reported designs either work efficiently only at moderate to high Reynolds numbers (Re), or require a complex 3D channel geometry that is often difficult to fabricate. In this paper, we report design, simulation, fabrication and characterization of a planar passive microfluidic mixer capable of mixing at low Reynolds numbers. The design incorporates diamond-shaped obstructions within the microchannel to break-up and recombine the flow. Simulation and experimental results of the developed micromixer show excellent mixing performance over a wide range of flow conditions (numerically: 0.01 < Re < 100, experimentally: 0.02 < Re < 10). The micromixer is also characterized by low pressure drop, an important characteristic for integration into complex, cascading microfluidic systems. Due to the simple planar structure of the micromixer, it can be easily realized and integrated with on- chip microfluidic systems, such as micro total analysis systems (mu TAS) or lab on a chip (LOC).
引用
收藏
页码:1017 / 1024
页数:8
相关论文
共 32 条
[1]   STIRRING BY CHAOTIC ADVECTION [J].
AREF, H .
JOURNAL OF FLUID MECHANICS, 1984, 143 (JUN) :1-21
[2]   Passive micromixer with obstructions for lab-on-a-chip applications [J].
Bhagat, AAS ;
Dagani, G ;
Peterson, ETK ;
Lee, JH ;
Papautsky, I .
Microfluidics, BioMEMS, and Medical Microsystems III, 2005, 5718 :291-297
[3]   Re-usable quick-release interconnect for characterization of microfluidic systems [J].
Bhagat, Ali Asgar S. ;
Jothimuthu, Preetha ;
Pais, Andrea ;
Papautsky, Ian .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (01) :42-49
[4]  
BORMAN S, 1999, CHEM ENG NEWS, V5, P30
[5]   Fast mixing by lamination. [J].
Branebjerg, J ;
Gravesen, P ;
Krog, JP ;
Nielsen, CR .
NINTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS, IEEE PROCEEDINGS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND SYSTEMS, 1996, :441-446
[6]  
Evans J, 1997, PROC IEEE MICR ELECT, P96
[7]  
Freemantle M, 1999, CHEM ENG NEWS, V77, P27, DOI 10.1021/cen-v077n044.p027
[8]   Passive micromixers for applications in the microreactor and μTAS fields [J].
Hardt, S ;
Drese, KS ;
Hessel, V ;
Schönfeld, F .
MICROFLUIDICS AND NANOFLUIDICS, 2005, 1 (02) :108-118
[9]   A picoliter-volume mixer for microfluidic analytical systems [J].
He, B ;
Burke, BJ ;
Zhang, X ;
Zhang, R ;
Regnier, FE .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :1942-1947
[10]   A novel in-plane passive microfluidic mixer with modified Tesla structures [J].
Hong, CC ;
Choi, JW ;
Ahn, CH .
LAB ON A CHIP, 2004, 4 (02) :109-113