On-line preconcentration of palladium on alumina microcolumns and determination in urban waters by inductively coupled plasma mass spectrometry

被引:75
作者
Moldovan, M [1 ]
Gómez, MM [1 ]
Palacios, MA [1 ]
机构
[1] Univ Complutense Madrid, Fac Ciencias Quim, Dept Quim Anal, E-28040 Madrid, Spain
关键词
palladium; water; preconcentration; alumina; interferences; ICP-MS;
D O I
10.1016/S0003-2670(02)01522-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for on-line preconcentration of palladium at ultra-trace level on alumina microcolumns and determination by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. A sampling time of 10 min (30 ml) and an eluent (KCN) volume of 300 mul provides a limit of detection of 1 ng l(-1). The precision was 4% at the 25 ng l(-1) level. The proposed system allows the on-line removal of the primary Pd-105 interferents (Cu and Y) providing the credible accuracy of the results. The proposed method is suitable for palladium determination in urban water samples. Platinum concentration in the analysed urban water samples was also determined. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 17 条
[1]   ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE PLATINUM BY FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY [J].
CANTARERO, A ;
GOMEZ, MM ;
CAMARA, C ;
PALACIOS, MA .
ANALYTICA CHIMICA ACTA, 1994, 296 (02) :205-211
[2]   DETERMINATION OF PLATINUM, PALLADIUM, RUTHENIUM AND IRIDIUM IN GEOLOGICAL SAMPLES BY ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY USING A SODIUM PEROXIDE FUSION AND TELLURIUM COPRECIPITATION [J].
ENZWEILER, J ;
POTTS, PJ ;
JARVIS, KE .
ANALYST, 1995, 120 (05) :1391-1396
[3]   AN ION-EXCHANGE METHOD FOR SELECTIVE SEPARATION OF PALLADIUM, PLATINUM AND RHODIUM FROM SOLUTIONS OBTAINED BY LEACHING AUTOMOTIVE CATALYTIC-CONVERTERS [J].
GAITA, R ;
ALBAZI, SJ .
TALANTA, 1995, 42 (02) :249-255
[4]   On-line removal of mass interferences in palladium determination by ICP-MS using modified capillaries coupled to micro-flow nebulizers [J].
García, R ;
Gómez, M ;
Palacios, MA ;
Bettmer, J ;
Camara, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) :481-486
[5]   Control of interferences in the determination of Pt, Pd and Rh in airborne particulate matter by inductively coupled plasma mass spectrometry [J].
Gomez, MB ;
Gomez, MM ;
Palacios, MA .
ANALYTICA CHIMICA ACTA, 2000, 404 (02) :285-294
[6]  
Hidalgo MM, 1996, FRESEN J ANAL CHEM, V354, P420
[7]   Assessment of Dowex 1-X8-based anion-exchange procedures for the separation and determination of ruthenium, rhodium, palladium, iridium, platinum and gold in geological samples by inductively coupled plasma mass spectrometry [J].
Jarvis, I ;
Totland, MM ;
Jarvis, KE .
ANALYST, 1997, 122 (01) :19-26
[8]  
KENAWY IM, 1987, ANALUSIS, V15, P314
[9]   Analytical problems in the determination of platinum-group metals in urine by quadrupole and magnetic sector field inductively coupled plasma mass spectrometry [J].
Krachler, M ;
Alimonti, A ;
Petrucci, F ;
Irgolic, KJ ;
Forastiere, F ;
Caroli, S .
ANALYTICA CHIMICA ACTA, 1998, 363 (01) :1-10
[10]   FLOW INJECTION INDUCTIVELY COUPLED PLASMA SPECTROMETRY - A NEW STRATEGY FOR ULTRATRACE ANALYSIS [J].
MCLEOD, CW ;
ZHANG, Y ;
COOK, I ;
COX, A ;
DATE, AR ;
CHEUNG, YY .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03) :462-464