Detect of Escherichia coli O157:H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors

被引:46
作者
Campbell, Gossett A.
Uknalis, Joe
Tu, Shu-I
Mutharasan, Raj [1 ]
机构
[1] Drexel Univ, Dept Chem & Biol Engn, Philadelphia, PA 19104 USA
[2] USDA ARS, Eastern Reg Res Ctr, NAA, Wyndmoor, PA 19038 USA
关键词
resonance frequency; mass change; flow cell;
D O I
10.1016/j.bios.2006.05.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors consisting of a piezoelectric and a borosilicate glass layer with a sensing area of 4 mm(2) were fabricated. An antibody specific to Escherichia coli (anti-E. coli) O157:1-17 was immobilized on PEMC sensors, and exposed to samples containing E. coli O157:1-17 (EC) prepared in various matrices: (1) broth, broth plus raw ground beef, and broth plus sterile ground beef without inoculation of E. coli O157:H7 served as controls, (2) 100mL of broth inoculated with 25 EC cells, (3) 100mL of broth containing 25 g of raw ground beef and (4) 100 mL of broth with 25 g of sterile ground beef inoculated with 25 EC cells. The total resonant frequency change obtained for the broth plus EC samples were 16 +/- 2 Hz (n = 2), 30 Hz (n = 1), and 54 2 Hz (n = 2) corresponding to 2, 4, and 6 h growth at 37 degrees C, respectively. The response to the broth plus 25 g of sterile ground beef plus EC cells were 21 +/- 2 Hz (n = 2), 37 Hz (n = 1), and 70 +/- 2 Hz (n = 2) corresponding to 2, 4, and 6 h, respectively. In all cases, the three different control samples yielded a frequency change of O-2 Hz (n = 6). The E. coli O157:H7 concentration in each broth and beef samples was determined by both plating and by pathogen modeling program. The results indicate that the PENIC sensor detects E. coli O157:H7 reliably at 50-100 cells/mL with a 3 mL sample. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1296 / 1302
页数:7
相关论文
共 18 条
[1]  
*AM ASS FOOD HYG V, 1996, NEW O GRAM, V20, P16
[2]   Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers [J].
Campbell, GA ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) :462-473
[3]   Escherichia coli O157:H7 detection limit of millimeter-sized PZT cantilever sensors is 700 Cells/mL [J].
Campbell, GA ;
Mutharasan, R .
ANALYTICAL SCIENCES, 2005, 21 (04) :355-357
[4]   Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1 mL/min [J].
Campbell, Gossett A. ;
Mutharasan, Raj .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (01) :78-85
[5]   A 6 x 6 drop plate method for simultaneous colony counting and MPN enumeration of Campylobacter jejuni, Listeria monocytogenes, and Escherichia coli [J].
Chen, CY ;
Nace, GW ;
Irwin, PL .
JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 55 (02) :475-479
[6]  
*FED REG, 1991, FED REGISTER, V54, P27544
[7]  
Greenberg A. E., 1992, STANDARD METHODS EXA
[8]   Immuno-magnetic bead mass transport and capture efficiency at low target cell densities in phosphate-buffered saline [J].
Irwin, P ;
Damert, W ;
Brewster, J ;
Gehring, A ;
Tu, SI .
JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 2002, 10 (02) :129-147
[9]   Genomic analysis using pulsed-field gel electrophoresis of Escherichia coli O157:H7 isolated from dairy calves during the United States national dairy heifer evaluation project (1991-1992) [J].
Lee, MS ;
Kaspar, CW ;
Brosch, R ;
Shere, J ;
Luchansky, JB .
VETERINARY MICROBIOLOGY, 1996, 48 (3-4) :223-230
[10]   Escherichia coli O157 and Salmonella infections associated with sprouts in California, 1996-1998 [J].
Mohle-Boetani, JC ;
Farrar, JA ;
Werner, SB ;
Minassian, D ;
Bryant, R ;
Abbott, S ;
Slutsker, L ;
Vugia, DJ .
ANNALS OF INTERNAL MEDICINE, 2001, 135 (04) :239-247