Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers

被引:79
作者
Campbell, GA [1 ]
Mutharasan, R [1 ]
机构
[1] Drexel Univ, Dept Chem Engn, Philadelphia, PA 19104 USA
关键词
resonant; pathogen; anti body-immobilized; high sensitivity; selectivity;
D O I
10.1016/j.bios.2004.11.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Composite self-excited PZT-glass cantilevers (5 and 3 mm in length, 1.8 and 2.0 mm wide) were fabricated and their resonance characteristics were determined in air and at I turn liquid immersion. In air, resonance occurred at 65.8 and 63.4 kHz for the two cantilevers used in this paper. Monoclonal antibody (MAb) specific to the pathogen Escherichia coli (E. coli) O157:H7 was immobilized at the cantilever glass tip, and then exposed to pathogen in the concentration range of 7 x 102 to 7 x 10(7) bacteria/mL. Resonance of the second mode decreased due to pathogen attachment in accordance with a proposed kinetic model. The specific attachment rate constant was found to be 3 x 10(-9) to 5 x 10(-9) min(-1) (cell/mL)(-1). Exposure to a mixed population containing both a pathogenic and non-pathogenic strain showed that the antibody-immobilized cantilever is highly selective, thus demonstrating its usefulness for detecting water-borne pathogens. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:462 / 473
页数:12
相关论文
共 33 条
[1]   Development of nanomechanical biosensors for detection of the pesticide DDT [J].
Alvarez, M ;
Calle, A ;
Tamayo, J ;
Lechuga, LM ;
Abad, A ;
Montoya, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :649-653
[2]  
*AM ASS FOOD HYG V, 1996, FSIS PUBL FIN RUL PA
[3]   Atomic force microscopic study of specific antigen/antibody binding [J].
BrowningKelley, ME ;
WaduMesthrige, K ;
Hari, V ;
Liu, GY .
LANGMUIR, 1997, 13 (02) :343-350
[4]  
CASS T, 1998, IMMOBILIZED BIOMOLEC, P4
[5]  
*CDCP, 1997, COLORADO WEEKLY REP, V43, P777
[6]   Specific antigen/antibody interactions measured by force microscopy [J].
Dammer, U ;
Hegner, M ;
Anselmetti, D ;
Wagner, P ;
Dreier, M ;
Huber, W ;
Guntherodt, HJ .
BIOPHYSICAL JOURNAL, 1996, 70 (05) :2437-2441
[7]   Adsorption-desorption noise in micromechanical resonant structures [J].
Djuric, Z ;
Jaksic, O ;
Randjelovic, D .
SENSORS AND ACTUATORS A-PHYSICAL, 2002, 96 (2-3) :244-251
[8]   Eigenfrequencies of a rectangular atomic force microscope cantilever in a medium [J].
Elmer, FJ ;
Dreier, M .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (12) :7709-7714
[9]   Modification of micro-cantilever sensors with sol-gels to enhance performance and immobilize chemically selective phases [J].
Fagan, BC ;
Tipple, CA ;
Xue, ZL ;
Sepaniak, MJ ;
Datskos, PG .
TALANTA, 2000, 53 (03) :599-608
[10]   ADHESION FORCES BETWEEN INDIVIDUAL LIGAND-RECEPTOR PAIRS [J].
FLORIN, EL ;
MOY, VT ;
GAUB, HE .
SCIENCE, 1994, 264 (5157) :415-417