Reproducibility of Black Blood Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Aortic Plaques of Atherosclerotic Rabbits

被引:31
作者
Calcagno, Claudia [1 ,2 ]
Vucic, Esad [1 ,2 ]
Mani, Venkatesh [1 ,2 ,3 ,4 ]
Goldschlager, Gregg [5 ]
Fayad, Zahi A. [1 ,2 ,3 ,4 ]
机构
[1] Mt Sinai Sch Med, Translat & Mol Imaging Inst, Imaging Sci Labs, New York, NY 10029 USA
[2] Mt Sinai Sch Med, Dept Radiol, New York, NY 10029 USA
[3] Mt Sinai Hosp, Zena & Michael A Wiener Cardiovasc Inst, New York, NY 10029 USA
[4] Mt Sinai Hosp, Marie Josee & Henry R Kravis Cardiovasc Hlth Ctr, New York, NY 10029 USA
[5] Mt Sinai Sch Med, Ctr Comparat Med & Surg, New York, NY 10029 USA
基金
美国国家卫生研究院;
关键词
DCE-MRI; atherosclerosis; neovascularization; reproducibility; POSITRON-EMISSION-TOMOGRAPHY; F-18-FDG PET; DCE-MRI; INFLAMMATION; MACROPHAGE; RUPTURE; DISEASE; BURDEN; MUSCLE; MODEL;
D O I
10.1002/jmri.22225
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the short-term reproducibility of black-blood dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in atherosclerotic rabbits to evaluate the potential of this technique to be a reliable read-out of plaque progression and/or regression upon therapeutic intervention. Materials and Methods: Atherosclerotic rabbits were imaged at baseline and 24 hours later with DCE-MRI on a 1.5T MRI system. DCE-MRI images were analyzed by calculating the area under the signal intensity versus time curve (AUC). Intraclass correlation coefficients (ICCs) were used to evaluate interscan, intraobserver, and interobserver reproducibility. In addition, the test-retest coefficient of variation (Coy) was evaluated. Results: Statistical analyses showed excellent interscan, intraobserver, and interobserver agreement. All ICCs were greater than 0.75, P < 0.01 indicating excellent agreement between measurements. Conclusion: Experimental results show good interscan and excellent intra- and interobserver reproducibility, suggesting that DCE-MRI could be used in preclinical settings as a read-out for novel therapeutic interventions for atherosclerosis. This preliminary work encourages investigating the reproducibility of DCE-MRI also in clinical settings, where it could be used for monitoring high-risk patients and in longitudinal clinical drug trials.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 25 条
[1]   Detection of neovessels in atherosclerotic plaques of rabbits using dynamic contrast enhanced MRI and 18F-FDG PET [J].
Calcagno, Claudia ;
Cornily, Jean-Christophe ;
Hyafil, Fabien ;
Rudd, James H. F. ;
Briley-Saebo, Karen C. ;
Mani, Venkatesh ;
Goldschlager, Gregg ;
Machac, Josef ;
Fuster, Valentin ;
Fayad, Zahi A. .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2008, 28 (07) :1311-1317
[2]   Radionuclide imaging for the detection of inflammation in vulnerable plaques [J].
Davies, JR ;
Rudd, JHF ;
Weissberg, PL ;
Narula, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (08) :C57-C68
[3]  
Davies JR, 2004, J NUCL MED, V45, P1898
[4]  
DAVIES MJ, 1993, BRIT HEART J, V69, P377
[5]   Cross-sectional, prospective study of MRI reproducibility in the assessment of plaque burden of the carotid arteries and aorta [J].
El Aidi, Hamza ;
Mani, Venkatesh ;
Weinshelbaum, Karen B. ;
Aguiar, Silvia H. ;
Taniguchi, Hiroaki ;
Postley, John E. ;
Samber, Daniel D. ;
Cohen, Emil I. ;
Stern, Jessica ;
van der Geest, Rob J. ;
Reiber, Johan H. C. ;
Woodward, Mark ;
Fuster, Valentin ;
Gidding, Samuel S. ;
Fayad, Zahi A. .
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2009, 6 (03) :219-228
[6]   STATISTICAL METHODOLOGY FOR THE CONCURRENT ASSESSMENT OF INTERRATER AND INTRARATER RELIABILITY - USING GONIOMETRIC MEASUREMENTS AS AN EXAMPLE [J].
ELIASZIW, M ;
YOUNG, SL ;
WOODBURY, MG ;
FRYDAYFIELD, K .
PHYSICAL THERAPY, 1994, 74 (08) :777-788
[7]  
FAUCI AS, 2008, HARRISONS PRINCIPLES, pCH218
[8]   Reproducibility of dynamic contrast-enhanced MRI in human muscle and tumours: comparison of quantitative and semi-quantitative analysis [J].
Galbraith, SM ;
Lodge, MA ;
Taylor, NJ ;
Rustin, GJS ;
Bentzen, S ;
Stirling, JJ ;
Padhani, AR .
NMR IN BIOMEDICINE, 2002, 15 (02) :132-142
[9]   Biobanks and the search for predictive biomarkers of local and systemic outcome in atherosclerotic disease [J].
Hurks, Rob ;
Peeters, Wouter ;
Derksen, Wouter J. M. ;
Hellings, Willem E. ;
Hoefer, Imo ;
Moll, Frans L. ;
de Kleijn, Dominique P. V. ;
Pasterkamp, Gerard .
THROMBOSIS AND HAEMOSTASIS, 2009, 101 (01) :48-54
[10]   Reproducibility of quantitative dynamic contrast-enhanced MRI in newly presenting glioma [J].
Jackson, A ;
Jayson, GC ;
Li, KL ;
Zhu, XP ;
Checkley, DR ;
Tessier, JJL ;
Waterton, JC .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (903) :153-162