On-line desalting and carbohydrate analysis for immobilized enzyme hydrolysis of waste cellulosic biomass by column-switching high-performance liquid chromatography

被引:20
作者
Cheng, Cheanyeh [1 ,2 ]
Chen, Chi-Sung [1 ]
Hsieh, Pei-Hsin [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Chem, Chungli 32023, Taiwan
[2] Chung Yuan Christian Univ, Res Ctr Anal & Identificat, Chungli 32023, Taiwan
关键词
On-line desalting; Carbohydrate analysis; Column-switching high-performance liquid chromatography; Immobilized enzyme hydrolysis; Waste cellulosic biomass; ANION-EXCHANGE CHROMATOGRAPHY; PULSED AMPEROMETRIC DETECTION; MASS-SPECTROMETRY; CELLULASE HYDROLYSATE; PAPER CELLULOSE; REVERSED-PHASE; HPLC; PRODUCTS; SAMPLES; SUGARS;
D O I
10.1016/j.chroma.2010.01.084
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
An innovative green column-switching high-performance liquid chromatographic (HPLC) technique was developed by coupling traditional and Pb(2+) ion-exclusion columns to study enzyme hydrolysis components of waste cellulosic biomass. Pure water was used as the mobile phase to separate neutral polar analytes in high salt content solution. The column-switching HPLC-RI was connected on-line to the immobilized enzyme reactor for successive on-line desalting and simultaneous analysis of six carbohydrates (cellobiose, glucose, xylose, galactose, mannose, and arabinose) in the hydrolysate of waste paper and waste tree branch by incorporating the heart-cut and the elution-time-difference techniques. Six internal standard calibration curves in the linear concentration range of 0-2000 mu g mL(-1) were prepared. Xylitol was used as the internal standard to give excellent linear correlation coefficients (0.9984-0.9999). The limits of detection and quantification for cellobiose, glucose, xylose, galactose, mannose, and arabinose varied between 0.12-4.88 and 0.40-16.3 mu g mL(-1), respectively, with an accuracy of 90-102% and a precision of 0.1-7.8%. Cellulose and hemicellulose contents were higher in waste paper than in waste tree branch. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2104 / 2110
页数:7
相关论文
共 45 条
[11]
On-line cut-off technique and organic modifier addition aided signal enhancement for trace analysis of carbohydrates in cellulase hydrolysate by ion exclusion chromatography-electrospray ionization mass spectrometry [J].
Cheng, Cheanyeh ;
Tsai, Hsiang-Rong ;
Chang, Kuo-Chung .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1119 (1-2) :188-196
[12]
Cellulase activity in different buffering media during waste paper hydrolysis by HPLC [J].
Cheng, CY .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1998, 45 (05) :679-688
[13]
Simultaneous determination of organic acids, sugars, and alcohols in musts and wines by an improved ion-exclusion HPLC method [J].
Chinnici, F ;
Spinabelli, U ;
Amati, A .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2002, 25 (16) :2551-2560
[14]
Coco F. lo, 2006, Journal of Liquid Chromatography & Related Technologies, V29, P2733
[15]
Simultaneous quantification of sulfamethoxazole and trimethoprim in whole egg samples by column-switching high-performance liquid chromatography using restricted access media column for on-line sample clean-up [J].
de Paula, F. C. C. R. ;
de Pietro, A. C. ;
Cass, Q. B. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :221-226
[16]
Eberendu AR, 2005, J AOAC INT, V88, P998
[17]
Determination of sugars, and some other compounds in infant formulae, follow-up milks and human milk by HPLC-UV/RI [J].
Ferreira, IMPLVO ;
Gomes, AMP ;
Ferreira, MA .
CARBOHYDRATE POLYMERS, 1998, 37 (03) :225-229
[18]
Determination of rat brain kynurenic acid by column-switching HPLC with fluorescence detection [J].
Fukushima, Takeshi ;
Mitsuhashi, Shogo ;
Tomiya, Masayuki ;
Kawai, Junko ;
Hashimoto, Kenji ;
Toyo'oka, Toshimasa .
BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (05) :514-519
[19]
High-throughput biopolymer desalting by solid-phase extraction prior to mass spectrometric analysis [J].
Gilar, M ;
Belenky, A ;
Wang, BH .
JOURNAL OF CHROMATOGRAPHY A, 2001, 921 (01) :3-13
[20]
Comprehensive analysis of branched aliphatic D-amino acids in mammals using an integrated multi-loop two-dimensional column-switching high-performance liquid chromatographic system combining reversed-phase and enantioselective columns [J].
Hamase, Kenji ;
Morikawa, Akiko ;
Ohgusu, Tornohiro ;
Lindner, Wolfgang ;
Zaitsu, Kiyoshi .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :105-111