Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

被引:51
作者
Wang, JH
Hansen, EH
机构
[1] Tech Univ Denmark, Dept Chem, DK-2800 Lyngby, Denmark
[2] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110006, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
ETAAS; flow injection; Lab-on-Valve; on-line sample pretreatment; sequential injection;
D O I
10.1016/j.trac.2004.08.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e., Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in recent decades is amply demonstrated by the large number of publications to which it has given rise. Among these, its hyphenation with electrothermal atomic absorption spectrometry (ETAAS) is one of the most attractive sub-branches because of the high sensitivity of ETAAS instruments for metal species. After a decade of development, it is apparent from the literature that coupling FI sample pretreatment with ETAAS remains most dynamic in the new millenium; meanwhile, it is exciting to note that some novel trends associated with this subject have also emerged. The aim of this mini-review is thus to illustrate the state-of-the-art progress in implementing miniaturized FI/SI systems for on-line separation and preconcentration of trace metals with detection by ETAAS since 2000. We also discuss future perspectives in this field. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 38 条
[1]   Flow injection on-line electrothermal atomic absorption spectrometry [J].
Alonso, EV ;
de Torres, AG ;
Pavón, JMC .
TALANTA, 2001, 55 (02) :219-232
[2]   Exploiting sequential injection analysis with bead injection and lab-on-valve for determination of lead using electrothermal atomic absorption spectrometry [J].
Ampan, P ;
Ruzicka, J ;
Atallah, R ;
Christian, GD ;
Jakmunee, J ;
Grudpan, K .
ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) :167-172
[3]   Cobalt ultra-trace on-line preconcentration and determination using a PTFE turnings packed column and electrothermal atomic absorption spectrometry. Applications in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1330-1334
[4]   Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (11) :1400-1403
[5]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[6]   Selective preconcentration and determination of tributyltin in fresh water by electrothermal atomic absorption spectrometry [J].
Bermejo-Barrera, P ;
Anllo-Sendín, RM ;
Cantelar-Barbazán, MJ ;
Bermejo-Barrera, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (7-8) :837-839
[7]   An on-line flow-injection microwave-assisted mineralization and a precipitation/dissolution system for the determination of molybdenum in blood serum and whole blood by electrothermal atomic absorption spectrometry [J].
Burguera, JL ;
Burguera, M ;
Rondón, C .
TALANTA, 2002, 58 (06) :1167-1175
[8]   Flow injection-electrothermal atomic absorption spectrometry configurations: recent developments and trends [J].
Burguera, JL ;
Burguera, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) :1801-1829
[9]   Determination of beryllium in natural and waste waters using on-line flow-injection preconcentration by precipitation/dissolution for electrothermal atomic absorption spectrometry [J].
Burguera, JL ;
Burguera, M ;
Rondón, C ;
Carrero, P ;
Brunetto, MR ;
de Peña, YP .
TALANTA, 2000, 52 (01) :27-37
[10]   A flow injection-ETAAS system for the on-line determination of total and dissolved silica in waters [J].
Burguera, M ;
Burguera, JL ;
Carrero, P ;
Rondón, C .
TALANTA, 2002, 58 (06) :1157-1166