Metrics for glycaemic control - from HbA1c to continuous glucose monitoring

被引:190
作者
Kovatchev, Boris P. [1 ,2 ,3 ]
机构
[1] Univ Virginia, Sch Med, 1215 Lee St, Charlottesville, VA 22908 USA
[2] Univ Virginia, Sch Engn & Appl Sci, Thornton Hall,POB 400259, Charlottesville, VA 22904 USA
[3] Univ Virginia, Sch Med, Ctr Diabet Technol, Ivy Translat Res Bldg,560 Ray C Hunt Dr, Charlottesville, VA 22903 USA
关键词
CLOSED-LOOP CONTROL; MEAN BLOOD-GLUCOSE; HYPOGLYCEMIA BEGETS HYPOGLYCEMIA; HEMOGLOBIN GLYCATION INDEX; ESTIMATED AVERAGE GLUCOSE; ARTIFICIAL PANCREAS; PLASMA-GLUCOSE; DIABETES COMPLICATIONS; CLINICAL-IMPLICATIONS; RACIAL-DIFFERENCES;
D O I
10.1038/nrendo.2017.3
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
As intensive treatment to lower levels of HbA(1c) characteristically results in an increased risk of hypoglycaemia, patients with diabetes mellitus face a life-long optimization problem to reduce average levels of glycaemia and postprandial hyperglycaemia while simultaneously avoiding hypoglycaemia. This optimization can only be achieved in the context of lowering glucose variability. In this Review, I discuss topics that are related to the assessment, quantification and optimal control of glucose fluctuations in diabetes mellitus. I focus on markers of average glycaemia and the utility and/or shortcomings of HbA(1c) as a 'gold-standard' metric of glycaemic control; the notion that glucose variability is characterized by two principal dimensions, amplitude and time; measures of glucose variability that are based on either self-monitoring of blood glucose data or continuous glucose monitoring (CGM); and the control of average glycaemia and glucose variability through the use of pharmacological agents or closed-loop control systems commonly referred to as the 'artificial pancreas'. I conclude that HbA(1c) and the various available metrics of glucose variability reflect the management of diabetes mellitus on different timescales, ranging from months (for HbA(1c)) to minutes (for CGM). Comprehensive assessment of the dynamics of glycaemic fluctuations is therefore crucial for providing accurate and complete information to the patient, physician, automated decision-support or artificial-pancreas system.
引用
收藏
页码:425 / 436
页数:12
相关论文
共 120 条
[61]
An Innovative Mathematical Model: A Key to the Riddle of HbA1c [J].
Kahrom, Mahdi .
INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2010, 2010
[62]
Racial Disparity in A1C Independent of Mean Blood Glucose in Children With Type 1 Diabetes [J].
Kamps, Jadi L. ;
Hempe, James M. ;
Chalew, Stuart A. .
DIABETES CARE, 2010, 33 (05) :1025-1027
[63]
Disparities in HbA1c levels between African-American and non-Hispanic white adults with diabetes -: A meta-analysis [J].
Kirk, Julienne K. ;
D'Agostino, Ralph B., Jr. ;
Bell, Ronny A. ;
Passmore, Leah V. ;
Bonds, Denise E. ;
Karter, Andrew J. ;
Narayan, K. M. Venkat .
DIABETES CARE, 2006, 29 (09) :2130-2136
[64]
Kovatchev B.P., 2001, J THEORETICAL MED, V3, P1
[65]
Feasibility of Long-Term Closed-Loop Control: A Multicenter 6-Month Trial of 24/7 Automated Insulin Delivery [J].
Kovatchev, Boris ;
Cheng, Peiyao ;
Anderson, Stacey M. ;
Pinsker, Jordan E. ;
Boscari, Federico ;
Buckingham, Bruce A. ;
Doyle, Francis J., III ;
Hood, Korey K. ;
Brown, Sue A. ;
Breton, Marc D. ;
Chernavvsky, Daniel ;
Bevier, Wendy C. ;
Bradley, Paige K. ;
Bruttomesso, Daniela ;
Del Favero, Simone ;
Calore, Roberta ;
Cobelli, Claudio ;
Avogaro, Angelo ;
Ly, Trang T. ;
Shanmugham, Satya ;
Dassau, Eyal ;
Kollman, Craig ;
Lum, John W. ;
Beck, Roy W. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (01) :18-+
[66]
The Artificial Pancreas in 2016: A Digital Treatment Ecosystem for Diabetes [J].
Kovatchev, Boris ;
Tamborlane, William V. ;
Cefalu, William T. ;
Cobelli, Claudio .
DIABETES CARE, 2016, 39 (07) :1123-1126
[67]
Glucose Variability: Timing, Risk Analysis, and Relationship to Hypoglycemia in Diabetes [J].
Kovatchev, Boris ;
Cobelli, Claudio .
DIABETES CARE, 2016, 39 (04) :502-510
[68]
Kovatchev Boris, 2008, J Diabetes Sci Technol, V2, P158
[69]
[70]
Kovatchev Boris P, 2005, Diabetes Technol Ther, V7, P849, DOI 10.1089/dia.2005.7.849