3D-Segmentation of the 18F-choline PET signal for target volume definition in radiation therapy of the prostate

被引:25
作者
Ciernik, I. Frank [1 ]
Brown, Derek W.
Schmid, Daniel
Hany, Thomas
Egli, Peter
Davis, J. Bernard
机构
[1] Univ Zurich Hosp, Clin Res Ctr, CH-8091 Zurich, Switzerland
[2] Osped San Giovanni Bellinzona, Oncol Inst So Switzerland, Bellinzona, Switzerland
[3] Univ Zurich Hosp, Dept Radiat Oncol, CH-8091 Zurich, Switzerland
[4] Univ Zurich Hosp, Dept Nucl Med, CH-8091 Zurich, Switzerland
关键词
PET; functional imaging; image-guided therapy; prostate cancer; PET/CT (18)fluoro-choline; radiotherapy planning; and radiation oncology;
D O I
10.1177/153303460700600104
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Volumetric assessment of PET signals becomes increasingly relevant for radiotherapy (RT) planning. Here, we investigate the utility of F-18-choline PET signals to serve as a structure for semi-automatic segmentation for forward treatment planning of prostate cancer. F-18-choline PET and CT scans of ten patients with histologically proven prostate cancer without extracapsuiar growth were acquired using a combined PET/CT scanner. Target volumes were manually delineated on CT images using standard software. Volumes were also obtained from F-18-choline PET images using an asymmetrical segmentation algorithm. PTVs were derived from CT F-18-choline PET based clinical target volumes (CTVs) by automatic expansion and comparative planning was performed. As a read-out for dose given to non-target structures, dose to the rectal wall was assessed. Planning target volumes (PTVs) derived from CT and F-18-choline PET yielded comparable results. Optimal matching of CT and F-18-choline PET derived volumes in the lateral and cranial-caudal directions was obtained using a background-subtracted signal thresholds of 23.0+/-2.6%. In antero-posterior direction, where adaptation compensating for rectal signal overflow was required, optimal matching was achieved with a threshold of 49.5+/-4.6%. 3D-conformal planning with CT or F-18-choline PET resulted in comparable doses to the rectal wall. Choline PET signals of the prostate provide adequate spatial information amendable to standardized asymmetrical region growing algorithms for PET-based target volume definition for external beam RT.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 38 条
[1]
[Anonymous], 1999, 62 ICRU
[2]
Defining a radiotherapy target with positron emission tomography [J].
Black, QC ;
Grills, IS ;
Kestin, LL ;
Wong, CYO ;
Wong, JW ;
Martinez, AA ;
Yan, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1272-1282
[3]
Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer [J].
Bradley, J ;
Thorstad, WL ;
Mutic, S ;
Miller, TR ;
Dehdashti, F ;
Siegel, BA ;
Bosch, W ;
Bertrand, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01) :78-86
[4]
Bradley JD, 2004, J NUCL MED, V45, p96S
[5]
Automated functional image-guided radiation treatment planning for rectal cancer [J].
Ciernik, IF ;
Huser, M ;
Burger, C ;
Davis, JB ;
Szekely, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :893-900
[6]
Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT):: A feasibility study [J].
Ciernik, IF ;
Dizendorf, E ;
Baumert, BG ;
Reiner, B ;
Burger, C ;
Davis, JB ;
Lütolf, UM ;
Steinert, HC ;
Von Schulthess, GK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :853-863
[7]
Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients:: accuracy, reproducibility and consistency [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Cosnard, G ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :237-245
[8]
Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios:: influence of reconstruction algorithms [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Doumont, T ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :247-250
[9]
DAVIS JB, 2006, RADIOTHER ONCOL, V74, P66
[10]
Impact of computed tomography and 18F-deoxyglucose coincidence detection emission tomography image fusion for optimization of conformal radiotherapy in non-small-cell lung cancer [J].
Deniaud-Alexandre, E ;
Touboul, E ;
Lerouge, D ;
Grahek, D ;
Foulquier, JN ;
Petegnief, Y ;
Grès, B ;
El Balaa, H ;
Keraudy, K ;
Kerrou, K ;
Montravers, F ;
Milleron, B ;
Lebeau, B ;
Talbot, JN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (05) :1432-1441