Accuracy and Sensitivity of Computed Tomography-Guided Percutaneous Needle Biopsy of Pulmonary Hilar Lymph Nodes

被引:19
作者
Avritscher, Rony
Krishnamurthy, Savitri [2 ]
Ensor, Joe [3 ]
Gupta, Sanjay
Tam, Alda
Madoff, David C.
Murthy, Ravi
Hicks, Marshall E.
Wallace, Michael J. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Sect Intervent Radiol, Unit 325, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Pathol, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
关键词
lung cancer; lymphoma; computed tomography; pneumothorax; CELL LUNG-CANCER; SITE CYTOPATHOLOGIC EXAMINATION; COAXIAL CUTTING NEEDLE; ASPIRATION BIOPSY; MEDIASTINAL LYMPHADENOPATHY; OUTPATIENT MANAGEMENT; LESIONS; CT; PNEUMOTHORAX; DIAGNOSIS;
D O I
10.1002/cncr.24968
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BACKGROUND: Because of their proximity to the pulmonary artery or vein, hilar lymph nodes are routinely biopsied with endobronchial or endoscopic ultrasonography (EUS)-guided fine-needle aspiration biopsy (FNAB). Computed tomography (CT)-guided percutaneous needle biopsy (PNB) allows the operator to acquire a larger core needle biopsy (CNB) when initial samples are inconclusive, when the suspected disease is not optimally diagnosed with FNAB, or when biomarkers are required. The purpose of this study was to retrospectively evaluate the sensitivity and accuracy of CT-guided PNB in patients with hilar adenopathy. METHODS: The authors identified 80 patients who underwent 81 CT-guided PNBs of pulmonary hilar lesions from October 2002 through December 2006 and retrospectively reviewed their medical and imaging records. The PNB sensitivity and accuracy were calculated in each case, and each case was reviewed for complications, including pneumothorax and subsequent thoracostomy tube insertion. RESULTS: PNB included FNAB and CNB in 81(100%) and 14 (17%) procedures, respectively. Data on 69 PNB specimens (67 FNAB specimens and 13 CNB specimens) were available for statistical analysis. Overall, PNB had a sensitivity of 91.4% (95% confidence interval [Cl], 81.0%-97.1%) and an accuracy rate of 92.8% (95% Cl, 83.9%-97.1%). Pneumothoraxes occurred in 39 patients (48%), 26 (32%) of whom required thoracostomy tube insertion. CONCLUSIONS: CT-guided PNB of pulmonary hilar lesions has high sensitivity and accuracy and represents a viable alternative for endobronchial ultrasound- or EUS-guided FNAB when larger biopsy samples are required for diagnosis or biomarker analysis. However, the procedure can result in high rates of pneumothorax. Cancer 2010;116:1974-80. (C) 2010 American Cancer Society
引用
收藏
页码:1974 / 1980
页数:7
相关论文
共 39 条
[1]   FINE-NEEDLE ASPIRATION BIOPSY OF MEDIASTINAL MASSES - EVALUATION OF 136 EXPERIENCES [J].
ADLER, OB ;
ROSENBERGER, A ;
PELEG, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (05) :893-896
[2]   TRANSTHORACIC ASPIRATION BIOPSY OF PULMONARY AND MEDIASTINAL LESIONS [J].
ARIZA, MAD ;
AGUIRAN, ERA ;
ATANCE, JLV ;
NUEZ, JT ;
LEITA, JTP ;
OLIVARES, MDA ;
AREVALO, JLB .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 12 (02) :98-103
[3]   Expression of the Receptor Tyrosine Kinase EphA2 Is Increased in Smokers and Predicts Poor Survival in Non-Small Cell Lung Cancer [J].
Brannan, Jennifer M. ;
Dong, Wenli ;
Prudkin, Ludmila ;
Behrens, Carmen ;
Lotan, Reuben ;
Bekele, B. Nebiyou ;
Wistuba, Ignacio ;
Johnson, Faye M. .
CLINICAL CANCER RESEARCH, 2009, 15 (13) :4423-4430
[4]   The accuracy of EUS-FNA in assessing mediastinal lymphadenopathy and staging patients with NSCLC [J].
Caddy, G ;
Conron, M ;
Wright, G ;
Desmond, P ;
Hart, D ;
Chen, RY .
EUROPEAN RESPIRATORY JOURNAL, 2005, 25 (03) :410-415
[5]  
*DEP DEF, 2005, BIOM BAS APPR TARG T, P257
[6]   Somatic mutations affect key pathways in lung adenocarcinoma [J].
Ding, Li ;
Getz, Gad ;
Wheeler, David A. ;
Mardis, Elaine R. ;
McLellan, Michael D. ;
Cibulskis, Kristian ;
Sougnez, Carrie ;
Greulich, Heidi ;
Muzny, Donna M. ;
Morgan, Margaret B. ;
Fulton, Lucinda ;
Fulton, Robert S. ;
Zhang, Qunyuan ;
Wendl, Michael C. ;
Lawrence, Michael S. ;
Larson, David E. ;
Chen, Ken ;
Dooling, David J. ;
Sabo, Aniko ;
Hawes, Alicia C. ;
Shen, Hua ;
Jhangiani, Shalini N. ;
Lewis, Lora R. ;
Hall, Otis ;
Zhu, Yiming ;
Mathew, Tittu ;
Ren, Yanru ;
Yao, Jiqiang ;
Scherer, Steven E. ;
Clerc, Kerstin ;
Metcalf, Ginger A. ;
Ng, Brian ;
Milosavljevic, Aleksandar ;
Gonzalez-Garay, Manuel L. ;
Osborne, John R. ;
Meyer, Rick ;
Shi, Xiaoqi ;
Tang, Yuzhu ;
Koboldt, Daniel C. ;
Lin, Ling ;
Abbott, Rachel ;
Miner, Tracie L. ;
Pohl, Craig ;
Fewell, Ginger ;
Haipek, Carrie ;
Schmidt, Heather ;
Dunford-Shore, Brian H. ;
Kraja, Aldi ;
Crosby, Seth D. ;
Sawyer, Christopher S. .
NATURE, 2008, 455 (7216) :1069-1075
[7]   Multimodality bronchoscopic diagnosis of peripheral lung lesions - A randomized controlled trial [J].
Eberhardt, Ralf ;
Anantham, Devanand ;
Ernst, Armin ;
Feller-Kopman, David ;
Herth, Felix .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2007, 176 (01) :36-41
[8]   EUS-guided FNA of the left adrenal gland in patients with thoracic or GI malignancies [J].
Eloubeidi, MA ;
Seewald, S ;
Tamhane, A ;
Brand, B ;
Chen, VK ;
Yasuda, I ;
Cerfolio, RJ ;
Omar, S ;
Topalidis, T ;
Wilcox, M ;
Soehendra, N .
GASTROINTESTINAL ENDOSCOPY, 2004, 59 (06) :627-633
[9]   Endoscopic ultrasound-guided fine needle aspiration of mediastinal lymph node in patients with suspected lung cancer after positron emission tomography and computed tomography scans [J].
Eloubeidi, MA ;
Cerfolio, RJ ;
Chen, VK ;
Desmond, R ;
Syed, S ;
Ojha, B .
ANNALS OF THORACIC SURGERY, 2005, 79 (01) :263-268
[10]   CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate [J].
Geraghty, PR ;
Kee, ST ;
McFarlane, G ;
Razavi, MK ;
Sze, DY ;
Dake, MD .
RADIOLOGY, 2003, 229 (02) :475-481