Kinetic analysis of water transfer through stratum corneum by a ventilated chamber measurement system

被引:1
作者
Endo, K [1 ]
Suzuki, N
Hoshi, M
Sato, M
Kato, T
Endo, A
Fujikura, Y
机构
[1] Kao Corp, Analyt Res Ctr, Haga 3213497, Japan
[2] Utsunomiya Univ, Fac Engn, Dept Appl Chem, Utsunomiya, Tochigi 3218585, Japan
关键词
skin barrier function; mass transfer coefficient; water vapor pressure; transepidermal water loss;
D O I
10.1252/jcej.36.138
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
For a detailed analysis of the water barrier function of skin, it is necessary to obtain effective physical parameters related to the rate of transepidermal water loss (TEWL). By using a modified ventilated chamber measurement system, with high sensitivity and response, we have determined the apparent mass transfer coefficient of water, K, for the stratum corneum (SC) and the water vapor pressure, P-d, at the interface between SC and underlying living cells of epidermis from analyses of water distribution in the contact zone of carrier gas and skin surface. By data fit optimization of the calculated water flux to the measured one, the in vivo K value for human skin was determined to be (0.30 +/- 0.14) x 10(-8) kg/(m(2.)s(.)Pa) (n = 4, mean +/- SD) which is close to the corresponding in vitro value of (0.12 +/- 0.02) x 10(-8) kg/(m(2.)s(.)Pa) (n = 6, mean +/- SD) for porcine SC membranes. It is, therefore, concluded that the apparent mass transfer coefficient of water for SC can be estimated in vivo and noninvasively by the method developed in this study and will lead to a more precise and reliable evaluation of skin barrier function than the rate of TEWL itself.
引用
收藏
页码:138 / 146
页数:9
相关论文
共 28 条
[11]   INVITRO PERMEABILITY OF SKIN AND BUCCAL MUCOSA TO SELECTED DRUGS AND TRITIATED-WATER [J].
GALEY, WR ;
LONSDALE, HK ;
NACHT, S .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1976, 67 (06) :713-717
[12]   STRATUM-CORNEUM LIPID PHASE-TRANSITIONS AND WATER BARRIER PROPERTIES [J].
GOLDEN, GM ;
GUZEK, DB ;
KENNEDY, AH ;
MCKIE, JE ;
POTTS, RO .
BIOCHEMISTRY, 1987, 26 (08) :2382-2388
[13]   Homogeneous transport in a heterogeneous membrane: Water diffusion across human stratum corneum in vivo [J].
Kalia, YN ;
Pirot, F ;
Guy, RH .
BIOPHYSICAL JOURNAL, 1996, 71 (05) :2692-2700
[14]   PREPARATION OF ISOLATED SHEETS OF HUMAN STRATUM CORNEUM [J].
KLIGMAN, AM ;
CHRISTOPHEL, E .
ARCHIVES OF DERMATOLOGY, 1963, 88 (06) :702-&
[15]  
LIRON Z, 1993, J PHARM SCI, V83, P692
[16]   A MICROBALANCE TECHNIQUE FOR MEASURING WATER-VAPOR UPTAKE AND RELEASE BY STRATUM-CORNEUM INVITRO [J].
MICHNIAKMIKOLAJCZAK, BB ;
BARRY, BW ;
WALLER, IL .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1986, 31 (03) :247-259
[17]   MEASUREMENT OF WATER EXCHANGE THROUGH SKIN [J].
NILSSON, GE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1977, 15 (03) :209-218
[18]   A new computer-based evaporimeter system for rapid and precise measurements of water diffusion through stratum corneum in vitro [J].
Norlén, L ;
Engblom, J ;
Andersson, M ;
Forslind, B .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1999, 113 (04) :533-540
[19]  
ONEILL JJ, 1965, J COLLOID INTERF SCI, V25, P57
[20]   Stratum corneum thickness and apparent water diffusivity:: Facile and noninvasive quantitation in vivo [J].
Pirot, F ;
Berardesca, E ;
Kalia, YN ;
Singh, M ;
Maibach, HI ;
Guy, RH .
PHARMACEUTICAL RESEARCH, 1998, 15 (03) :492-494