Serial dilution microchip for cytotoxicity test

被引:33
作者
Bang, H [1 ]
Lim, SH
Lee, YK
Chung, S
Chung, C
Han, DC
Chang, JK
机构
[1] Seoul Natl Univ, Sch Mech & Aerosp Engn, Seoul 151742, South Korea
[2] Digital Bio Technol Co, Seoul 151742, South Korea
[3] Seoul Natl Univ, Sch Elect Engn & Comp Sci, Seoul 151742, South Korea
关键词
D O I
10.1088/0960-1317/14/8/007
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Today's pharmaceutical industry is facing challenges resulting from the vast increases in sample numbers produced by high-throughput screening (HTS). In addition, the bottlenecks created by increased demand for cytotoxicity testing (required to assess compound safety) are becoming a serious problem. We have developed a polymer PDMS (polydimethylsiloxane) based microfluidic device that can perform a cytotoxicity test in a rapid and reproducible manner. The concept that the device includes is well adjustable to automated robots in huge HTS systems, so we can think of it as a potential dilution and delivery module. Cytotoxicity testing is all about the dilution and dispensing of a drug sample. Previously, we made a PDMS based microfluidic device which automatically and precisely diluted drugs with a buffer solution with serially increasing concentrations. This time, the serially diluted drug solution was directly delivered to 96 well plates for cytotoxicity testing. Cytotoxic paclitaxel solution with 2% RPMl 1640 has been used while carrying out cancerous cell based cytotoxicity tests. We believe that this rapid and robust use of the PDMS microchip will overcome the growing problem in cytotoxicity testing for HTS.
引用
收藏
页码:1165 / 1170
页数:6
相关论文
共 19 条
[1]  
Beebe D J, 2001, MEC IND, V2, P343
[2]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[3]   Formation of natural pH gradients in a microfluidic device under flow conditions: Model and experimental validation [J].
Cabrera, CR ;
Finlayson, B ;
Yager, P .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :658-666
[4]  
CHENG SB, P MICR BANFF CAN, P145
[5]   Generation of gradients having complex shapes using microfluidic networks [J].
Dertinger, SKW ;
Chiu, DT ;
Jeon, NL ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1240-1246
[6]  
Georgiadis MS, 1997, CLIN CANCER RES, V3, P449
[7]  
IAN F, 2001, CELL BIOL TOXICOL, V17, P213
[8]   Generation of solution and surface gradients using microfluidic systems [J].
Jeon, NL ;
Dertinger, SKW ;
Chiu, DT ;
Choi, IS ;
Stroock, AD ;
Whitesides, GM .
LANGMUIR, 2000, 16 (22) :8311-8316
[9]  
JUN KC, 2003, MICROSYST TECHNOL, V9, P555
[10]  
KEVIN S, 2001, ANAL BIOTECHNOL, V12, P70