Use of pulse oximetry for blood pressure measurement after cardiac surgery

被引:8
作者
Movius, AJ [1 ]
Bratton, SL [1 ]
Sorensen, GK [1 ]
机构
[1] Univ Washington, Dept Anesthesiol, Sch Med, Seattle, WA 98195 USA
关键词
pulse oximeter; oscillometric blood pressure; arterial catheter; children;
D O I
10.1136/adc.78.5.457
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Blood pressure measurement using pulse oximeter waveform change was compared with an oscillometric measurement and the gold standard, intra-arterial measurement, in children after cardiac surgery. Forty six patients were enrolled and divided into groups according to weight. Simultaneous blood pressure measurements were obtained from the arterial catheter, the oscillometric device, and the pulse oximeter. Pulse oximeter measurements were obtained with a blood pressure cuff proximal to the oximeter probe. The blood pressure measurements from the pulse oximeter method correlated better with intra-arterial measurements than those from the oscillometric device (0.77-0.96 v 0.42-0.83). The absolute differences between the pulse oximeter and intra-arterial measurements were significantly smaller than between the oscillometric and intra-arterial measurements in children less than 15.0 kg. The pulse oximeter waveform change is an accurate and reliable way to measure blood pressure in children non-invasively, and is superior to the oscillometric method for small patients.
引用
收藏
页码:457 / 460
页数:4
相关论文
共 20 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   ARTERIAL-PRESSURE MEASUREMENT IN PRETERM INFANTS [J].
BRIASSOULIS, G .
CRITICAL CARE MEDICINE, 1986, 14 (08) :735-738
[3]   CAN PULSE OXIMETRY BE USED TO MEASURE SYSTOLIC BLOOD-PRESSURE [J].
CHAWLA, R ;
KUMARVEL, V ;
GIRDHAR, KK ;
SETHI, AK ;
INDRAYAN, A ;
BHATTACHARYA, A .
ANESTHESIA AND ANALGESIA, 1992, 74 (02) :196-200
[4]   OXIMETRY IN PULSELESS DISEASE [J].
CHAWLA, R ;
KUMARVEL, V ;
GIRDHAR, KK ;
SETHI, AK ;
BHATTACHARYA, A .
ANAESTHESIA, 1990, 45 (11) :992-993
[5]   RELIABILITY OF THE DINAMAP NONINVASIVE MONITOR IN THE MEASUREMENT OF BLOOD-PRESSURE OF III ASIAN NEWBORNS [J].
CHIA, F ;
ANG, AT ;
WONG, TW ;
TAN, KW ;
FUNG, KP ;
LEE, J ;
KHIN, K .
CLINICAL PEDIATRICS, 1990, 29 (05) :262-267
[6]  
CILLEY R, 1992, SEMIN PEDIAT SURG, V1930, P174
[7]  
Crapanzano MS, 1996, PEDIATRICS, V97, P220
[8]   DINAMAP FAILS TO DETECT HYPOTENSION IN VERY-LOW-BIRTH-WEIGHT INFANTS [J].
DIPROSE, GK ;
EVANS, DH ;
ARCHER, LNJ ;
LEVENE, MI .
ARCHIVES OF DISEASE IN CHILDHOOD, 1986, 61 (08) :771-773
[9]  
FRIESEN RH, 1981, ANESTH ANALG, V60, P742
[10]   AN AUTOMATED OSCILLOMETRIC TECHNIQUE FOR ESTIMATING MEAN ARTERIAL-PRESSURE IN CRITICALLY ILL NEWBORNS [J].
KIMBLE, KJ ;
DARNALL, RA ;
YELDERMAN, M ;
ARIAGNO, RL ;
REAM, AK .
ANESTHESIOLOGY, 1981, 54 (05) :423-425