Three-dimensional BANG™ gel dosimetry in conformal carbon ion radiotherapy

被引:57
作者
Ramm, U
Weber, U
Bock, M
Krämer, M
Bankamp, A
Damrau, M
Thilmann, C
Bottcher, HD
Schad, LR
Kraft, G
机构
[1] Univ Frankfurt Klinikum, ZRad, Klin Strahlentherapie, D-60590 Frankfurt, Germany
[2] GSI, D-64291 Darmstadt, Germany
[3] Deutsch Krebsforschungszentrum, Heidelberg, Germany
关键词
D O I
10.1088/0031-9155/45/9/401
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study we applied BANG(TM) polymer-gel dosimetry using magnetic resonance imaging (MRI) to densely ionizing radiation such as carbon ion beams. BANGTM polymer gels were irradiated with a quadratic field of monoenergetic C-12 ions at different beam energies in the range of 135 MeV u(-1) to 410 MeV u(-1). They were irradiated at the radiotherapy facility of the GSI, Darmstadt, Germany. Our object was to examine the saturation effect for densely ionizing radiation that occurs at high values of linear energy transfer (LET). The examination yielded the first effectiveness values that will be discussed in the following sections. A solid sphere and a hollow sphere were both irradiated with a horizontal pencil beam from the raster scanning facility at energies of 268 MeV u(-1) (solid sphere) and 304 MeV u(-1) (hollow sphere) respectively. MR dosimetry measurements were compared with data from a planning system. As far as quality is concerned. there is good agreement between the measured dose distributions of both samples and the dose maps from the planning software. The measured MR signals cannot be converted into absolute dose, since the relative efficiency is still unknown for mixed radiation fields of primary carbon ions and it is known only to a limited extent for nuclear fragments with different energies from highly energetic photon radiation. Model calculations are in progress in order to facilitate conversions of measured MR signals into dose.
引用
收藏
页码:N95 / N102
页数:8
相关论文
共 16 条
[1]  
BACK SA, 1999, COMMUNICATION
[2]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[3]   Clinical delivery of intensity modulated conformal radiotherapy for relapsed or second-primary head and neck cancer using a multileaf collimator with dynamic control [J].
De Neve, W ;
De Gersem, W ;
Derycke, S ;
De Meerleer, G ;
Moerman, M ;
Bate, MT ;
Van Duyse, B ;
Vakaet, L ;
De Deene, Y ;
Mersseman, B ;
De Wagter, C .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :301-314
[4]   Efficiency of thermoluminescent detectors to heavy charged particles [J].
Geiss, OB ;
Kramer, M ;
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 142 (04) :592-598
[5]   MEASUREMENT OF RADIATION-DOSE DISTRIBUTIONS BY NUCLEAR MAGNETIC-RESONANCE (NMR) IMAGING [J].
GORE, JC ;
KANG, YS ;
SCHULZ, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10) :1189-1197
[6]   MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY [J].
HABERER, T ;
BECHER, W ;
SCHARDT, D ;
KRAFT, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) :296-305
[7]  
HABERER T, 1994, THESIS TH DARMSTADT
[8]  
Jakel O, 1998, PHYS MEDICA, V14, P53
[9]   Calculations of heavy-ion track structure [J].
Kramer, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 105 (1-4) :14-20
[10]   NMR RELAXATION ENHANCEMENT IN GELS POLYMERIZED AND CROSS-LINKED BY IONIZING-RADIATION - A NEW APPROACH TO 3D DOSIMETRY BY MRI [J].
MARYANSKI, MJ ;
GORE, JC ;
KENNAN, RP ;
SCHULZ, RJ .
MAGNETIC RESONANCE IMAGING, 1993, 11 (02) :253-258