摘要
In this study we applied BANG(TM) polymer-gel dosimetry using magnetic resonance imaging (MRI) to densely ionizing radiation such as carbon ion beams. BANGTM polymer gels were irradiated with a quadratic field of monoenergetic C-12 ions at different beam energies in the range of 135 MeV u(-1) to 410 MeV u(-1). They were irradiated at the radiotherapy facility of the GSI, Darmstadt, Germany. Our object was to examine the saturation effect for densely ionizing radiation that occurs at high values of linear energy transfer (LET). The examination yielded the first effectiveness values that will be discussed in the following sections. A solid sphere and a hollow sphere were both irradiated with a horizontal pencil beam from the raster scanning facility at energies of 268 MeV u(-1) (solid sphere) and 304 MeV u(-1) (hollow sphere) respectively. MR dosimetry measurements were compared with data from a planning system. As far as quality is concerned. there is good agreement between the measured dose distributions of both samples and the dose maps from the planning software. The measured MR signals cannot be converted into absolute dose, since the relative efficiency is still unknown for mixed radiation fields of primary carbon ions and it is known only to a limited extent for nuclear fragments with different energies from highly energetic photon radiation. Model calculations are in progress in order to facilitate conversions of measured MR signals into dose.
引用
收藏
页码:N95 / N102
页数:8
相关论文
共 16 条
[11]  
MARYANSKI MJ, 1999, P 1 INT WORKSH RAD T, P65
[12]   Image registration of BANG® gel dose maps for quantitative dosimetry verification [J].
Meeks, SL ;
Bova, FJ ;
Maryanski, MJ ;
Kendrick, LA ;
Ranade, MK ;
Buatti, JM ;
Friedman, WA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05) :1135-1141
[13]   MODIFIED SPIN-ECHO METHOD FOR MEASURING NUCLEAR RELAXATION TIMES [J].
MEIBOOM, S ;
GILL, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (08) :688-691
[14]   An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry [J].
Oldham, M ;
Baustert, I ;
Lord, C ;
Smith, TAD ;
McJury, M ;
Warrington, AP ;
Leach, MO ;
Webb, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1113-1132
[15]  
SCHOLZ M, 1994, RADIAT PROT DOSIM, V52, P29
[16]  
WEBER U, 2000, IN PRESS PHYS MED BI