摘要
Purpose: To determine incision sizes for 6-mm optic foldable intraocular lenses (IOLs) implanted with injector systems. Design: Nonrandomized, prospective clinical study. Participants: One hundred fifty eyes of 150 patients with cataract and without other anterior segment pathological features or previous eye surgeries. Intervention: We performed implantation of foldable IOLs with sharp optic edges and 6-mm total optic diameter with their recommended injector systems and cartridges: (1) Alcon MA60BM with Monarch II/cartridge A, (2) Alcon SA60AT with Monarch II/cartridge B, (3) Alcon SA60AT with Monarch II/cartridge C, (4) AMO AR40e with Unfolder Sapphire, (5) AMO AR40e with Unfolder Emerald, and (6) AMO Clariflex with Unfolder Silver. With every combination, 25 IOLs were implanted. Main Outcome Measures: We measured incision width before and after phacoemulsification as well as before and after IOL implantation using a Kohnen caliper. Results: The tunnel width (in millimeters; +/- standard deviation) for each combination before and after IOL implantation, respectively, was (1) 3.61 (+/-0.12) and 3.74 (+/-0.15), (2) 3.31 (+/-0.12) and 3.44 (+/-0.16), (3) 2.88 (+/-0.11) and 2.96 (+/-0.11), (4) 3.37 (+/-0.12) and 3.52 (+/-0.09), (5) 2.99 (+/-0.16) and 3.11 (+/-0.14), and (6) 3.06 (+/-0.12) and 3.15 (+/-0.11). The incision sizes before and after implantation for (3) were significantly smaller than all other combinations. Combinations (2) and (4) were not statistically significantly different, but were statistically significantly smaller in preimplantation and postimplantation incision size compared with combination (1) and were larger compared with combinations (5) and (6). However, the relationship of incision size and effective IOL optical zone differed: AR40e (Unfolder Sapphire) < MA60BM < Clariflex < AR40e (Unfolder Emerald) < SA60AT with both Monarch II B and C cartridge (greater means better relationship). Conclusions: Postimplantation incisions sizes of 2.96 to 3.74 mm were determined with 6-mm total optic foldable IOLs using Monarch and Unfolder injector systems. Because the effective optical zone size is different for some of these IOLs, the incision size alone may not be the only relevant factor for optical outcome. (C) 2005 by the American Academy of Ophthalmology.
引用
收藏
页码:58 / 66
页数:9
相关论文
共 25 条
[1]
Silicone plate-haptic lens injection without prior incision enlargement [J].
Coombes, AG ;
Sheard, R ;
Gartry, DS ;
Allan, BD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10) :1542-1544
[2]
Unfolder lens injection system with acrylic intraocular lenses: Retrospective study [J].
Gohill, J ;
Bhamra, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :980-982
[3]
THE CORRELATION BETWEEN INCISION SIZE AND CORNEAL SHAPE CHANGES IN SUTURELESS CATARACT-SURGERY [J].
HAYASHI, K ;
HAYASHI, H ;
NAKAO, F ;
HAYASHI, F .
OPHTHALMOLOGY, 1995, 102 (04) :550-556
[4]
Intraocular bacterial contamination during sutureless, small incision, single-port phacoemulsification [J].
John, T ;
Sims, M ;
Hoffmann, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (12) :1786-1791
[5]
Effect of temporal and nasal unsutured limbal tunnel incisions on induced astigmatism after phacoemulsification [J].
Kohnen, S ;
Neuber, R ;
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05) :821-825
[6]
Experimental and clinical evaluation of incision size and shape following forceps and injector implantation of a three-piece high-refractive-index silicone intraocular lens [J].
Kohnen, T ;
Koch, DD .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1998, 236 (12) :922-928
[7]
COMPARISON OF THE INDUCED ASTIGMATISM AFTER TEMPORAL CLEAR CORNEAL TUNNEL INCISIONS OF DIFFERENT SIZES [J].
KOHNEN, T ;
DICK, B ;
JACOBI, KW .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (04) :417-424
[8]
New caliper for small incision cataract surgery [J].
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) :1298-1300
[9]
Incision sizes with 5.5 mm total optic, 3-piece foldable intraocular lenses [J].
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (12) :1765-1772
[10]
Incision sizes for foldable intraocular lenses [J].
Kohnen, T ;
Lambert, RJ ;
Koch, DD .
OPHTHALMOLOGY, 1997, 104 (08) :1277-1286