Stator winding turn-fault for closed-loop induction motor drives

被引:123
作者
Tallam, RM [1 ]
Habetler, TG
Harley, RG
机构
[1] Rockwell Automat, Adv Technol, Milwaukee, WI 53204 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
关键词
AC drive; induction machine; negative sequence; neural network (NN); stator winding turn fault;
D O I
10.1109/TIA.2003.811784
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sensorless diagnostics for line-connected machines is based on extracting fault signatures from the spectrum of the line currents. However, for closed-loop drives, the power supply is a regulated current source and, hence, the-motor voltages must also be monitored for fault information. In this paper, a previously proposed neural network scheme for turn-fault detection in line-connected induction machines is extended to inverter-fed machines, with special emphasis on closed-loop drives. Experimental results are provided to illustrate that the method is impervious to machine and instrumentation nonidealities, and that it requires lesser data memory and computation requirements than existing schemes, which are based on data lookup tables.
引用
收藏
页码:720 / 724
页数:5
相关论文
共 8 条
[1]  
Cash M.A, 1998, IEEE IAS ANN M, V01, P299
[2]  
Kliman GB, 1996, IEEE IND APPLIC SOC, P687, DOI 10.1109/IAS.1996.557113
[3]  
Sottile J, 2000, IEEE IND APPLIC SOC, P2682
[4]  
Tallam RM, 2001, IEEE POWER ELECTRON, P2224, DOI 10.1109/PESC.2001.954450
[5]   Transient model for induction machines with stator winding turn faults [J].
Tallam, RM ;
Habetler, TG ;
Harley, RG .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (03) :632-637
[6]  
Tallam RM, 2000, IEEE IND APPLIC SOC, P375, DOI 10.1109/IAS.2000.881138
[7]   ANALYSIS OF CAGE INDUCTION-MOTORS WITH STATOR WINDING FAULTS [J].
WILLIAMSON, S ;
MIRZOIAN, K .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (07) :1838-1842
[8]  
Wolbank TM, 1999, IEE CONF PUBL, P253, DOI 10.1049/cp:19991029