Patency failures in microvascular prosthetic grafts

被引:3
作者
Bravo, C
Tichy, F
Misek, I
Horky, D
Stastna, M
Valka, J
Vesely, J
机构
[1] Univ Vet & Pharmaceut Sci, Fac Vet Med, Dept Anat Histol & Embryol, Brno 61242, Czech Republic
[2] Masaryk Univ, Fac Med, Dept Plast Surg, Brno, Czech Republic
[3] Masaryk Univ, Fac Med, Dept Histol & Embryol, Brno, Czech Republic
[4] Inst Knitting Res, Brno, Czech Republic
[5] Laurea Clin, Brno, Czech Republic
关键词
microsurgery; graft; structure; vessel; experimental medicine;
D O I
10.2754/avb199766030183
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Thirty knitted prosthetic grafts (calibre 2 mm, length 10 mm) of three different types were implanted into abdominal aorta of Wistar rats. The types were as follows: Type 1 (n=10), multifilamentous Dacron coated with polyurethane; Type 2 (n=10), monofilamentous Dacron coated with polyurethane; type 3 (n=10) multifilamentous Dacron coated with polylactide. The patency rates of the grafts were 10% after 1 month, and 0% after 2 months. The prostheses proved unworkable owing to high incidence of acute thrombosis, lack of endothelium formation, chondrification, and formation of collateral blood sinuses.
引用
收藏
页码:183 / +
页数:13
相关论文
共 25 条
[21]   USE OF THE 3M PRECISE MICROVASCULAR ANASTOMOTIC SYSTEM IN GRAFTING 1-MM DIAMETER ARTERIES WITH POLYTETRAFLUOROETHYLENE PROSTHESES - A LONG-TERM STUDY [J].
LANZETTA, M ;
OWEN, ER .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1993, 9 (03) :173-181
[22]  
MATSUMOTO H, 1973, SURGERY, V74, P519
[23]  
NICHTER L S, 1988, Microsurgery, V9, P235, DOI 10.1002/micr.1920090405
[24]  
NORDESTGAARD AG, 1986, BRIT J EXP PATHOL, V67, P839
[25]   DELAYED THROMBOSIS OF SYNTHETIC MICRO-VASCULAR BYPASS GRAFTS [J].
WEINSTEIN, PR ;
REINERT, RL ;
BRITTAIN, F .
NEUROSURGERY, 1981, 9 (03) :268-274