Stent fracture and restenosis after placement of a drug-eluting device in the vertebral artery origin and treatment with the stent-in-stent technique - Report of two cases

被引:19
作者
Kim, Seong-Rim
Baik, Min-Woo
Yoo, Seung-Hoon
Park, Ik-Seong
Kim, Sang-Don
Kim, Moon-Chan
机构
[1] Catholic Univ Korea, Holy Family Hosp, Dept Neurosurg, Puchon 420717, Kyeonggi Do, South Korea
[2] Catholic Univ Korea, Kangnam St Marys Hosp, Puchon 420717, Kyeonggi Do, South Korea
关键词
stent fracture; in-stent stenosis; vertebral artery; surgical technique;
D O I
10.3171/jns.2007.106.5.907
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The authors report two cases of stent fracture and restenosis after placement of a drug-eluting device in the vertebral artery (VA) origin, and describe management of restenosis with the stent-in-stent technique. Two women, one 62 and the other 67 years of age, underwent stent placement in the VA origin to treat symptomatic and angiographically significant stenosis in this vessel. Sirolimus-eluting coronary stents (Cypher) were used in both cases. Four months after placement of the devices, the symptoms recurred. Follow-up angiography performed 5 months after insertion of the devices revealed a transverse stent fracture with separation of the fragments and severe in-stent restenosis in both cases. The restenoses were treated with reinsertion of coronary stents (Cypher and Jostent FlexMaster) by using the stent-in-stent technique. After stent reinsertion, the patients exhibited relief of symptoms. This paper is the first report of fracture in a drug-eluting stent and restenosis after stent placement in the VA origin. Restenosis caused by such a fracture can be managed successfully by performing the stent-in-stent maneuver. The physical properties of metallic devices, stent strut geometry, and anatomical peculiarities of the subclavian artery may be associated with stent fractures. Earlier follow-up angiography studies (within 6 months) are warranted.
引用
收藏
页码:907 / 911
页数:5
相关论文
共 29 条
[1]
A reappraisal of angioplasty and stenting for the treatment of vertebral origin stenosis [J].
Albuquerque, FC ;
Fiorella, D ;
Han, P ;
Spetzler, RF ;
McDougall, CG .
NEUROSURGERY, 2003, 53 (03) :607-614
[2]
Fracture of popliteal artery stents [J].
Babalik, E ;
Gülbaran, M ;
Gürmen, T ;
Öztürk, S .
CIRCULATION JOURNAL, 2003, 67 (07) :643-645
[3]
A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents [J].
Babapulle, MN ;
Joseph, L ;
Bélisle, P ;
Brophy, JM ;
Eisenberg, MJ .
LANCET, 2004, 364 (9434) :583-591
[4]
Brilakis Emmanouil S, 2004, J Invasive Cardiol, V16, P545
[5]
Extracranial vertebral artery stent placement: in-hospital and follow-up results [J].
Chastain, HD ;
Campbell, MS ;
Iyer, S ;
Roubin, GS ;
Vitek, J ;
Mathur, A ;
Al-Mubarak, NA ;
Terry, JB ;
Yates, V ;
Kretzer, K ;
Alred, D ;
Gomez, CR .
JOURNAL OF NEUROSURGERY, 1999, 91 (04) :547-552
[6]
Stent-graft design: the good, the bad and the ugly [J].
Chuter, TAM .
CARDIOVASCULAR SURGERY, 2002, 10 (01) :7-13
[7]
Vertebral artery origin angioplasty and primary stenting: safety and restenosis rates in a prospective series [J].
Cloud, GC ;
Crawley, F ;
Clifton, A ;
McCabe, DJH ;
Brown, MM ;
Markus, HS .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2003, 74 (05) :586-590
[8]
Characteristics of metals used in implants [J].
Gotman, I .
JOURNAL OF ENDOUROLOGY, 1997, 11 (06) :383-389
[9]
Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis [J].
Halkin, A ;
Carlier, S ;
Leon, MB .
HEART, 2004, 90 (08) :e45
[10]
Mechanical failure of prosthetic human implants: A 10-year experience with aortic stent graft devices [J].
Jacobs, TS ;
Won, J ;
Gravereaux, EC ;
Faries, PL ;
Morrissey, N ;
Teodorescu, VJ ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (01) :16-26