Reliability of old and new ventricular fibrillation detection algorithms for automated external defibrillators

被引:108
作者
Amann, Anton [1 ,2 ]
Tratnig, Robert [3 ]
Unterkofler, Karl [3 ]
机构
[1] Innsbruck Med Univ, Dept Anesthesia & Gen Intens Care, Anichstr 35, A-6020 Innsbruck, Austria
[2] ETH Honggerberg, Dept Environm Sci, CH-8093 Zurich, Switzerland
[3] FH Vorarlberg, Res Ctr PPE, A-6850 Dornbirn, Austria
关键词
D O I
10.1186/1475-925X-4-60
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: A pivotal component in automated external defibrillators (AEDs) is the detection of ventricular fibrillation by means of appropriate detection algorithms. In scientific literature there exists a wide variety of methods and ideas for handling this task. These algorithms should have a high detection quality, be easily implementable, and work in real time in an AED. Testing of these algorithms should be done by using a large amount of annotated data under equal conditions. Methods: For our investigation we simulated a continuous analysis by selecting the data in steps of one second without any preselection. We used the complete BIH-MIT arrhythmia database, the CU database, and the files 7001 - 8210 of the AHA database. All algorithms were tested under equal conditions. Results: For 5 well-known standard and 5 new ventricular fibrillation detection algorithms we calculated the sensitivity, specificity, and the area under their receiver operating characteristic. In addition, two QRS detection algorithms were included. These results are based on approximately 330 000 decisions (per algorithm). Conclusion: Our values for sensitivity and specificity differ from earlier investigations since we used no preselection. The best algorithm is a new one, presented here for the first time.
引用
收藏
页数:15
相关论文
共 17 条
[1]   ALGORITHMIC SEQUENTIAL DECISION-MAKING IN THE FREQUENCY-DOMAIN FOR LIFE THREATENING VENTRICULAR ARRHYTHMIAS AND IMITATIVE ARTIFACTS - A DIAGNOSTIC SYSTEM [J].
BARRO, S ;
RUIZ, R ;
CABELLO, D ;
MIRA, J .
JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (04) :320-328
[2]   VENTRICULAR-FIBRILLATION DETECTION BY A REGRESSION TEST ON THE AUTOCORRELATION FUNCTION [J].
CHEN, S ;
THAKOR, NV ;
MOWER, MM .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (03) :241-249
[3]  
Clayton R. H., 1991, Proceedings. Computers in Cardiology (Cat. No.90CH3011-4), P515, DOI 10.1109/CIC.1990.144269
[4]   COMPARISON OF 4 TECHNIQUES FOR RECOGNITION OF VENTRICULAR-FIBRILLATION FROM THE SURFACE ECG [J].
CLAYTON, RH ;
MURRAY, A ;
CAMPBELL, RWF .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (02) :111-117
[5]   QUANTITATIVE INVESTIGATION OF QRS DETECTION RULES USING THE MIT/BIH ARRHYTHMIA DATABASE [J].
HAMILTON, PS ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) :1157-1165
[6]   Comparison of five algorithms for the detection of ventricular fibrillation from the surface ECG [J].
Jekova, I .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (04) :429-439
[7]  
Kerber RE, 1997, CIRCULATION, V95, P1677
[8]  
Kuo S., 1978, Computers in Cardiology 1978, P347
[9]   COMPLEXITY OF FINITE SEQUENCES [J].
LEMPEL, A ;
ZIV, J .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1976, 22 (01) :75-81
[10]   DETECTION OF ECG CHARACTERISTIC POINTS USING WAVELET TRANSFORMS [J].
LI, CW ;
ZHENG, CX ;
TAI, CF .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (01) :21-28