Determination of regional bone blood flow by means of fluorescent microspheres using an automated sample-processing procedure

被引:8
作者
Anetzberger, H
Thein, E
Walli, AK
Messmer, K
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Orthoped, D-8000 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Inst Surg Res, D-8000 Munich, Germany
[3] Univ Munich, Klinikum Grosshadern, Inst Clin Chem, D-8000 Munich, Germany
关键词
bone blood flow; fluorescent microspheres; animal experiments; RADIOACTIVE MICROSPHERES; LABELED MICROSPHERES; ORGAN PERFUSION; CARDIAC-OUTPUT; VALIDATION; CIRCULATION; FETUS; UTERO; ERROR; DOGS;
D O I
10.1159/000070604
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
The determination of regional blood flow utilizing fluorescent microspheres (FMs) is an established method for numerous organs. Recent progress, in particular the automation of sample processing, has further improved this method. However, the FM method (reference sample technique), which allows repetitive measurement of regional organ blood flow, has so far not been used for the determination of blood flow in bone. The aim of the present study was to establish FM for the quantification of regional bone blood flow (RBBF). Female, anesthetized New Zealand rabbits (n = 6) received left ventricular injections of different amounts of FM at six subsequent time points. In order to examine the precision of RBBF determination, two different FM species were injected simultaneously at the sixth injection. At the end of the experiments the femoral and tibial condyles of each hind limb were removed and the fluorescence intensity in the tissue samples was measured by an automated procedure. In an in vitro study we have shown that acid digestion of the crystalline matrix has no effect on the fluorescence characteristics of FM. The determination of the number of spheres per tissue sample revealed that depending on the tissue sample size up to 3 x 10(6) spheres/injection were necessary to obtain about 400 microspheres in the individual bone samples. RBBF values of the tibial and femoral condyles did not differ at various injection intervals. The tibial blood flow values varied between 6.6 +/- 1.1 and 8.5 +/- 1.4 ml/min/100 g and were significantly higher than those of the femur (4.3 +/- 1.1 to 6.0 +/- 1.8 ml/min/100 g). The bone blood flow values obtained by simultaneous injection of two FM species correlated significantly (r = 0.96, slope = 1.06, intercept = 0.05), the mean difference was 0.39 +/- 1.11 ml/min/100 g. Our data demonstrate that the measurement of RBBF by means of FM allows a valid determination of RBBF. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 41 条
[1]
MEASUREMENT OF CARDIAC-OUTPUT WITH AND ORGAN TRAPPING OF RADIOACTIVE MICROSPHERES [J].
ARCHIE, JP ;
FIXLER, DE ;
ULLYOT, DJ ;
HOFFMAN, JIE ;
UTLEY, JR ;
CARLSON, EL .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 35 (01) :148-154
[2]
INCREASED NUMBER OF MYOCARDIAL BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED MICROSPHERES [J].
BAER, RW ;
PAYNE, BD ;
VERRIER, ED ;
VLAHAKES, GJ ;
MOLODOWITCH, D ;
UHLIG, PN ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (03) :H418-H434
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Brookes M., 1998, BLOOD SUPPLY BONE SC, P75
[5]
SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[6]
ACUTE AND CHRONIC MICROSPHERE LOSS FROM CANINE LEFT-VENTRICULAR MYOCARDIUM [J].
CONSIGNY, PM ;
VERRIER, ED ;
PAYNE, BD ;
EDELIST, G ;
JESTER, J ;
BAER, RW ;
VLAHAKES, GJ ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 242 (03) :H392-H404
[7]
THE EARLY EFFECTS OF SYMPATHECTOMY ON BONE BLOOD-FLOW [J].
DAVIES, R ;
TOTHILL, P ;
HOOPER, G ;
FLEMING, RH ;
MCCARTHY, ID ;
HUGHES, SPF .
CALCIFIED TISSUE INTERNATIONAL, 1984, 36 (05) :622-624
[8]
RESPONSES OF BONE AND JOINT BLOOD-VESSELS IN CATS AND RABBITS TO ELECTRICAL-STIMULATION OF NERVES SUPPLYING THE KNEE [J].
FERRELL, WR ;
KHOSHBATEN, A ;
ANGERSON, WJ .
JOURNAL OF PHYSIOLOGY-LONDON, 1990, 431 :677-687
[9]
VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION [J].
GLENNY, RW ;
BERNARD, S ;
BRINKLEY, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) :2585-2597
[10]
MEASUREMENT OF BLOOD-FLOW TO BONE AND MARROW IN EXPERIMENTAL-ANIMALS BY MEANS OF THE MICROSPHERE TECHNIQUE - REVIEW [J].
GROSS, PM ;
MARCUS, ML ;
HEISTAD, DD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (06) :1028-1031