Comparison of flow parameters to analyse bolus kinetics of ultrasound contrast enhancement in a capillary flow model

被引:8
作者
Cangür, H [1 ]
Meyer-Wiethe, K [1 ]
Seidel, G [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Neurol, D-23358 Lubeck, Germany
来源
ULTRASCHALL IN DER MEDIZIN | 2004年 / 25卷 / 06期
关键词
ultrasound; flow model; bolus harmonic imaging; ultrasound contrast agent; perfusion microcirculation;
D O I
10.1055/s-2004-813796
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: Perfusion harmonic imaging is a new method to evaluate brain perfusion. The purpose of our study was to describe flow by analysing the kinetics of ultrasound contrast enhancement in a flow model after bolus injection of an ultrasound contrast agent (UCA). Methods: We performed an in-vitro study with an open-circuit flow model and SonoVue(R) given as bolus injection. Bolus kinetics was analysed by harmonic imaging (SONOS 5500, 1.8/3.6 MHz, MI: 1.6) at a fixed frame rate (0.67 Hz). Five different flow rates from 1.8 to 21.6 ml/min were tested. We generated time-intensity curves (TIC) from the grey scale loops. Five parameters (time-to-peak-intensity [TTP], peak-intensity [PI], area under the curve [AUC], positive gradient [PG] and full width at half maximum [FWHM]) were correlated with flow rate. Results: The analysis of both TTP and PG versus flow rate indicated a highly significant linear correlation (r = -0.96, P < .01; r = 0.91, P = .03; respectively). Neither the AUC (r = -0.67, P = .22), nor the PI (r = 0.68, P = .20) nor the FWHM (r = -0.63, P = .37) correlated significantly with flow rate. Conclusion: The relationship between TIC parameters and flow rates indicates that, in our flow model, the TTP and PG are the most robust and reliable parameters compared to the AUC, PI and FWHM.
引用
收藏
页码:418 / 421
页数:4
相关论文
共 18 条
[1]   Effects of shadowing on the time-intensity curves in contrast echocardiography: A phantom study [J].
Bos, LJ ;
Piek, JJ ;
Spaan, JAE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (02) :217-227
[2]   Quantification of flow rates using harmonic grey-scale imaging and an ultrasound contrast agent:: an in vitro and in vivo study [J].
Claassen, L ;
Seidel, G ;
Algermissen, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) :83-88
[3]   Quantification of blood flow [J].
Cosgrove, D ;
Eckersley, R ;
Blomley, M ;
Harvey, C .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1338-1344
[4]  
DEVVOYE I, 1986, NONUNIFORM RANDOM VA
[5]   Ultrasonic evaluation of pathological brain perfusion in acute stroke using second harmonic imaging [J].
Federlein, J ;
Postert, T ;
Meves, S ;
Weber, S ;
Przuntek, H ;
Büttner, T .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2000, 69 (05) :616-622
[6]   Second harmonic Imaging of the human brain -: The practicability of coronal insonation planes and alternative perfusion parameters [J].
Harrer, JU ;
Klötzsch, C .
STROKE, 2002, 33 (06) :1530-1535
[7]   ASSESSMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW WITH MYOCARDIAL CONTRAST TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
KAUL, S ;
KELLY, P ;
OLINER, JD ;
GLASHEEN, WP ;
KELLER, MW ;
WATSON, DD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (02) :468-482
[8]   Validation of ultrasound contrast destruction imaging for flow quantification [J].
Lucidarme, O ;
Kono, Y ;
Corbeil, J ;
Choi, SH ;
Mattrey, RF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (12) :1697-1704
[9]   Penumbral microcirculatory changes associated with peri-infarct depolarizations in the rat [J].
Pinard, E ;
Nallet, H ;
MacKenzie, ET ;
Seylaz, J ;
Roussel, S .
STROKE, 2002, 33 (02) :606-612
[10]   Contrast agent specific imaging modes for the ultrasonic assessment of parenchymal cerebral echo contrast enhancement [J].
Postert, T ;
Hoppe, P ;
Federlein, J ;
Helbeck, S ;
Ermert, H ;
Przuntek, H ;
Büttner, T ;
Wilkening, W .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (12) :1709-1716