Automated alignment of chromatographic data

被引:248
作者
Skov, Thomas [1 ]
van den Berg, Frans [1 ]
Tomasi, Giorgio [1 ]
Bro, Rasmus [1 ]
机构
[1] Univ Copenhagen, Fac Life Sci, Dept Food Sci, DK-1958 Frederiksberg C, Denmark
关键词
automated alignment; correlation optimised warping; peak area preservation; chromatographic data; optimisation;
D O I
10.1002/cem.1031
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper focuses on the practical aspects and implications of preprocessing chromatographic data to correct for undesirable time-shifts. An approach to automate the alignment of chromatographic data based on peak alignment or warping is proposed. This approach deals with selection of the required parameters including selection of reference sample to warp towards, and chooses warping settings based on a new evaluation criterion for goodness of correction. The new criterion aims at quantifying goodness of alignment while at the same time penalising significant shape or area-changes in the warped peaks. The entire selection procedure is automated using a discrete-coordinates simplex-like optimisation routine. Examples with simulated chromatographic data, GC-FID and HPLC-Fluorescence measurement series illustrate the potential of using this automated alignment tool. (C) Copyright 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:484 / 497
页数:14
相关论文
共 12 条
[1]   Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography-mass spectrometry data [J].
Bylund, D ;
Danielsson, R ;
Malmquist, G ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (02) :237-244
[2]   Chemical fingerprinting of petroleum biomarkers using time warping and PCA [J].
Christensen, JH ;
Tomasi, G ;
Hansen, AB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (01) :255-260
[3]   RETENTION TIME SHIFT ADJUSTMENTS OF 2-WAY CHROMATOGRAMS USING BESSELS INEQUALITY [J].
GRUNG, B ;
KVALHEIM, OM .
ANALYTICA CHIMICA ACTA, 1995, 304 (01) :57-66
[4]   A new criterion for simple-structure transformations of core arrays in N-way principal components analysis [J].
Henrion, R ;
Andersson, CA .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 47 (02) :189-204
[5]   Quantification of naphthalenes in jet fuel with GC x GC/Tri-PLS and windowed rank minimization retention time alignment [J].
Johnson, KJ ;
Prazen, BJ ;
Young, DC ;
Synovec, RE .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6) :410-416
[6]   Aligning of single and multiple wavelength chromatographic profiles for chemometric data analysis using correlation optimised warping [J].
Nielsen, NPV ;
Carstensen, JM ;
Smedsgaard, J .
JOURNAL OF CHROMATOGRAPHY A, 1998, 805 (1-2) :17-35
[7]   A comparison of two algorithms for warping of analytical signals [J].
Pravdova, V ;
Walczak, B ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 2002, 456 (01) :77-92
[8]   SEQUENTIAL APPLICATION OF SIMPLEX DESIGNS IN OPTIMISATION AND EVOLUTIONARY OPERATION [J].
SPENDLEY, W ;
HEXT, GR ;
HIMSWORTH, FR .
TECHNOMETRICS, 1962, 4 (04) :441-&
[9]   Correlation optimized warping and dynamic time warping as preprocessing methods for chromatographic data [J].
Tomasi, G ;
van den Berg, F ;
Andersson, C .
JOURNAL OF CHEMOMETRICS, 2004, 18 (05) :231-241
[10]  
TOMASI G, 2006, THESIS ROYAL VET AGR