Quantification of naphthalenes in jet fuel with GC x GC/Tri-PLS and windowed rank minimization retention time alignment

被引:56
作者
Johnson, KJ
Prazen, BJ
Young, DC
Synovec, RE
机构
[1] Univ Washington, Dept Chem, Ctr Proc Analyt Chem, Seattle, WA 98195 USA
[2] Chevron Res & Technol Co, Richmond, CA 94802 USA
关键词
GC x GC; chemometrics; jet fuel; retention time alignment;
D O I
10.1002/jssc.200301640
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Comprehensive, two-dimensional gas chromatography (GC x GC) is used in conjunction with trilinear partial least squares (Tri-PLS) to quantify the percent weight of naphthalenes (two-ring aromatic compounds) in jet fuel samples. The increased peak capacity and selectivity of GC: x GC makes the technique attractive for the rapid, and possibly less tedious analysis of jet fuel. The analysis of complex mixtures by GC x GC is further enhanced through the use of chemometric techniques, including those designed for use on 2-D data such as Tri-PLS. Unfortunately, retention time variation, unless corrected, can be an impediment to chemometric analysis. Previous work has demonstrated that the effects of retention time variation can be mitigated in sub-regions of GC x GC chromatograms through the application of an objective retention time alignment algorithm based on rank minimization. Building upon this previous work, it is demonstrated here that the effects of retention time variation can be mitigated throughout an entire GC x GC chromatogram with an objective retention time alignment algorithm based on windowed rank minimization alignment. A significant decrease in calibration error is observed when the algorithm is applied to chromatograms prior to construction of Tri-PLS models. Fourteen jet fuel samples with known weight percentages of naphthalenes (ASTM D1840) were obtained. Each sample was subjected to five replicate five-minute GC x GC separations over a period of two days. A subset of nine samples spanning the range of weight percentages of naphthalenes was chosen as a calibration set and Tri-PLS calibration models were subsequently developed in order to predict the naphthalene content of the samples from the GC x GC chromatograms of the remaining five samples. Calibration models constructed from GC x GC chromatograms that were retention time corrected are shown to exhibit a root mean square error of prediction of roughly half that of calibration models constructed from uncorrected chromatograms. The error of prediction is lowered further to a value that nearly matches the uncertainty in the standard percent weight values (ca. 1% of the median percent volume value) when the aligned chromatograms are truncated to include only regions of the chromatogram populated by naphthalenes and compounds of similar polarity and boiling point.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 22 条
[1]  
[Anonymous], 1987, BINDING CONSTANTS ME
[2]  
Bertsch W, 2000, HRC-J HIGH RES CHROM, V23, P167
[3]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[4]   Critical evaluation of two F-tests for selecting the number of factors in abstract factor analysis [J].
Faber, K ;
Kowalski, BR .
ANALYTICA CHIMICA ACTA, 1997, 337 (01) :57-71
[5]   ASPECTS OF PSEUDORANK ESTIMATION METHODS BASED ON THE EIGENVALUES OF PRINCIPAL COMPONENT ANALYSIS OF RANDOM MATRICES [J].
FABER, NM ;
BUYDENS, LMC ;
KATEMAN, G .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 25 (02) :203-226
[6]   ASPECTS OF PSEUDORANK ESTIMATION METHODS BASED ON AN ESTIMATE OF THE SIZE OF THE MEASUREMENT ERROR [J].
FABER, NM ;
BUYDENS, LMC ;
KATEMAN, G .
ANALYTICA CHIMICA ACTA, 1994, 296 (01) :1-20
[7]   Comprehensive two-dimensional gas chromatography and chemometrics for the high-speed quantitative analysis of aromatic isomers in a jet fuel using the standard addition method and an objective retention time alignment algorithm [J].
Fraga, CG ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4154-4162
[8]  
Fraga CG, 2000, HRC-J HIGH RES CHROM, V23, P215
[9]   Objective data alignment and chemometric analysis of comprehensive two-dimensional separations with run-to-run peak shifting on both dimensions [J].
Fraga, CG ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 2001, 73 (24) :5833-5840
[10]   Increasing the number of analyzable peaks in comprehensive two dimensional separations through chemometrics [J].
Fraga, CG ;
Bruckner, CA ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :675-683