Quantification of naphthalenes in jet fuel with GC x GC/Tri-PLS and windowed rank minimization retention time alignment

被引:56
作者
Johnson, KJ
Prazen, BJ
Young, DC
Synovec, RE
机构
[1] Univ Washington, Dept Chem, Ctr Proc Analyt Chem, Seattle, WA 98195 USA
[2] Chevron Res & Technol Co, Richmond, CA 94802 USA
关键词
GC x GC; chemometrics; jet fuel; retention time alignment;
D O I
10.1002/jssc.200301640
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Comprehensive, two-dimensional gas chromatography (GC x GC) is used in conjunction with trilinear partial least squares (Tri-PLS) to quantify the percent weight of naphthalenes (two-ring aromatic compounds) in jet fuel samples. The increased peak capacity and selectivity of GC: x GC makes the technique attractive for the rapid, and possibly less tedious analysis of jet fuel. The analysis of complex mixtures by GC x GC is further enhanced through the use of chemometric techniques, including those designed for use on 2-D data such as Tri-PLS. Unfortunately, retention time variation, unless corrected, can be an impediment to chemometric analysis. Previous work has demonstrated that the effects of retention time variation can be mitigated in sub-regions of GC x GC chromatograms through the application of an objective retention time alignment algorithm based on rank minimization. Building upon this previous work, it is demonstrated here that the effects of retention time variation can be mitigated throughout an entire GC x GC chromatogram with an objective retention time alignment algorithm based on windowed rank minimization alignment. A significant decrease in calibration error is observed when the algorithm is applied to chromatograms prior to construction of Tri-PLS models. Fourteen jet fuel samples with known weight percentages of naphthalenes (ASTM D1840) were obtained. Each sample was subjected to five replicate five-minute GC x GC separations over a period of two days. A subset of nine samples spanning the range of weight percentages of naphthalenes was chosen as a calibration set and Tri-PLS calibration models were subsequently developed in order to predict the naphthalene content of the samples from the GC x GC chromatograms of the remaining five samples. Calibration models constructed from GC x GC chromatograms that were retention time corrected are shown to exhibit a root mean square error of prediction of roughly half that of calibration models constructed from uncorrected chromatograms. The error of prediction is lowered further to a value that nearly matches the uncertainty in the standard percent weight values (ca. 1% of the median percent volume value) when the aligned chromatograms are truncated to include only regions of the chromatogram populated by naphthalenes and compounds of similar polarity and boiling point.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 22 条
[11]  
Johnson KJ, 2002, J SEP SCI, V25, P297, DOI 10.1002/1615-9314(20020401)25:5/6<297::AID-JSSC297>3.0.CO
[12]  
2-I
[13]   Pattern recognition of jet fuels: comprehensive GC x GC with ANOVA-based feature selection and principal component analysis [J].
Johnson, KJ ;
Synovec, RE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2002, 60 (1-2) :225-237
[14]  
Lee AL, 2000, J MICROCOLUMN SEP, V12, P187, DOI 10.1002/(SICI)1520-667X(2000)12:4<187::AID-MCS3>3.0.CO
[15]  
2-P
[16]   COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY USING AN ON-COLUMN THERMAL MODULATOR INTERFACE [J].
LIU, ZY ;
PHILLIPS, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) :227-231
[17]   Rank annihilation correction for the amendment of instrumental inconsistencies [J].
Maeder, M ;
Neuhold, YM ;
Olsen, A ;
Puxty, G ;
Dyson, R ;
Zilian, A .
ANALYTICA CHIMICA ACTA, 2002, 464 (02) :249-259
[18]  
Malinowski E.R., 1991, FACTOR ANAL CHEM
[19]   COMPREHENSIVE MULTIDIMENSIONAL GAS-CHROMATOGRAPHY [J].
PHILLIPS, JB ;
XU, JZ .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :327-334
[20]   Standardization of second-order chromatographic/spectroscopic data for optimum chemical analysis [J].
Prazen, BJ ;
Synovec, RE ;
Kowalski, BR .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :218-225