A biosensor chip by CMOS process for surface stress measurement in bioanalyte

被引:25
作者
Yang, S. M.
Yin, T. I.
Chang, C.
机构
[1] Institute of Aeronautics and Astronautics, National Cheng Kung University
关键词
microcantilever; biosensor; piezorestitive effect; CMOS process;
D O I
10.1016/j.snb.2006.10.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A 1 cm x 1 cm biosensor chip of integrated piezoresistive microcantilevers and microchannel is developed by CMOS process. The 125 Lm x 60 mu m x 1.1.1 mu m microcantilever is a 4-layer structure composed of an immobilized surface layer, a top insulation layer, an embedded piezoresistive layer, and a bottom insulation layer to measure in situ the surface stress change induced by biochemical reaction. The temperature drift in biosensing is minimized by operating in the static mode of surface stress measurement, and the intrinsic electrical noise is also effectively reduced by the parallel microcantilever design and on-chip signal conditioning circuit. The biosensor performance is validated by measuring the thiol-modified single strained DNA to demonstrate its measurement sensitivity. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:707 / 714
页数:8
相关论文
共 18 条
[1]   A cantilever array-based artificial nose [J].
Baller, MK ;
Lang, HP ;
Fritz, J ;
Gerber, C ;
Gimzewski, JK ;
Drechsler, U ;
Rothuizen, H ;
Despont, M ;
Vettiger, P ;
Battiston, FM ;
Ramseyer, JP ;
Fornaro, P ;
Meyer, E ;
Güntherodt, HJ .
ULTRAMICROSCOPY, 2000, 82 (1-4) :1-9
[2]  
BERGER R, 1998, APPL PHYS A, V66, P55
[3]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[4]  
Harley J. A., 2000, THESIS STANFORD U
[5]   Characterization of DNA probes immobilized on gold surfaces [J].
Herne, TM ;
Tarlov, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (38) :8916-8920
[6]   PIEZORESISTANCE EFFECT OF SILICON [J].
KANDA, Y .
SENSORS AND ACTUATORS A-PHYSICAL, 1991, 28 (02) :83-91
[7]   Analysis, control and augmentation of microcantilever deflections in bio-sensing systems [J].
Khaled, ARA ;
Vafai, K ;
Yang, M ;
Zhang, X ;
Ozkan, CS .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 94 (01) :103-115
[8]  
Madou M. J., 2001, FUNDAMENTAL MICROFAB
[9]   Microcantilever-based biosensors [J].
Moulin, AM ;
O'Shea, SJ ;
Welland, ME .
ULTRAMICROSCOPY, 2000, 82 (1-4) :23-31
[10]   POLYSILICON AS A MATERIAL FOR MICROSENSOR APPLICATIONS [J].
OBERMEIER, E ;
KOPYSTYNSKI, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1992, 30 (1-2) :149-155