DNA sequencing by capillary electrophoresis

被引:92
作者
Dovichi, NJ [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
DNA sequencing; capillary electrophoresis; scanning detectors;
D O I
10.1002/elps.1150181229
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electrophoresis has been under development for DNA sequencing since 1990. This development has traveled down two parallel tracks. The first track studied the details of DNA separation by gel electrophoresis. Early work stressed rapid separations at high electric fields, which reached the extreme of a 3.5 min sequencing run at 1200 V/cm. While fast separations are useful in clinical resequencing applications for mutation detection, long read-length is important in genomic sequencing. Unfortunately, sequence read-length degrades as electric field and sequencing speed increases; this tradeoff between read-length and sequencing speed appears to be a fundamental result of the physics of DNA separations in a polymer. The longest sequence sequencing read-lengths have been obtained at modest electric fields, high temperature, and with low concentration noncrosslinked polymers. In parallel with our understanding of DNA separations, the second track of DNA sequencing development considered the design of large-scale capillary instruments, wherein hundreds of DNA samples can be sequenced in parallel. Real-world application of these very high throughput capillary electrophoresis systems will require significant investment in sample preparation technology.
引用
收藏
页码:2393 / 2399
页数:7
相关论文
共 50 条
  • [1] A NONRADIOACTIVE AUTOMATED-METHOD FOR DNA-SEQUENCE DETERMINATION
    ANSORGE, W
    SPROAT, BS
    STEGEMANN, J
    SCHWAGER, C
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1986, 13 (06): : 315 - 323
  • [2] BAY S, 1993, P SOC PHOTO-OPT INS, V1891, P8, DOI 10.1117/12.146713
  • [3] SEPARATION OF FRAGMENTS UP TO 570 BASES IN LENGTH BY USE OF 6-PERCENT T-NON-CROSS-LINKED POLYACRYLAMIDE FOR DNA-SEQUENCING IN CAPILLARY ELECTROPHORESIS
    BEST, N
    ARRIAGA, E
    CHEN, DY
    DOVICHI, NJ
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (22) : 4063 - 4067
  • [4] RAPID DNA SEQUENCING BY HORIZONTAL ULTRATHIN GEL-ELECTROPHORESIS
    BRUMLEY, RL
    SMITH, LM
    [J]. NUCLEIC ACIDS RESEARCH, 1991, 19 (15) : 4121 - 4126
  • [5] Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions
    Carrilho, E
    RuizMartinez, MC
    Berka, J
    Smirnov, I
    Goetzinger, W
    Miller, AW
    Brady, D
    Karger, BL
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (19) : 3305 - 3313
  • [6] DNA-SEQUENCING BY CAPILLARY ELECTROPHORESIS - USE OF A 2-LASER 2-WINDOW INTENSIFIED DIODE-ARRAY DETECTION SYSTEM
    CARSON, S
    COHEN, AS
    BELENKII, A
    RUIZMARTINEZ, MC
    BERKA, J
    KARGER, BL
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (22) : 3219 - 3226
  • [7] 2-LABEL PEAK-HEIGHT ENCODED DNA SEQUENCING BY CAPILLARY GEL-ELECTROPHORESIS - 3 EXAMPLES
    CHEN, DY
    HARKE, HR
    DOVICHI, NJ
    [J]. NUCLEIC ACIDS RESEARCH, 1992, 20 (18) : 4873 - 4880
  • [8] HIGH-RESOLUTION SEPARATION OF OLIGONUCLEOTIDES AND DNA-SEQUENCING REACTION-PRODUCTS BY CAPILLARY ELECTROPHORESIS WITH LINEAR POLYACRYLAMIDE AND LASER-INDUCED FLUORESCENCE DETECTION
    CHEN, N
    MANABE, T
    TERABE, S
    YOHDA, M
    ENDO, I
    [J]. JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (06) : 539 - 543
  • [9] SEPARATION AND ANALYSIS OF DNA-SEQUENCE REACTION-PRODUCTS BY CAPILLARY GEL-ELECTROPHORESIS
    COHEN, AS
    NAJARIAN, DR
    KARGER, BL
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01): : 49 - 60
  • [10] Dovichi N. J., 1995, US Patent, Patent No. [5,439,578, 5439578]