Accelerated Slice Encoding for Metal Artifact Correction

被引:79
作者
Hargreaves, Brian A. [1 ]
Chen, Weitian [2 ]
Lu, Wenmiao [3 ]
Alley, Marcus T. [1 ]
Gold, Garry E. [1 ]
Brau, Anja C. S. [2 ]
Pauly, John M. [4 ]
Pauly, Kim Butts [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] GE Healthcare, Appl Sci Lab, Menlo Pk, CA USA
[3] Nanyang Technol Univ, Dept Elect & Elect Engn, Singapore, Singapore
[4] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
SEMAC; metal artifact; distortion; slice-encoding; artifact reduction; SIGNAL-TO-NOISE; MAGNETIC-RESONANCE; MRI; REDUCTION; SUSCEPTIBILITY; ACQUISITION;
D O I
10.1002/jmri.22112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To demonstrate accelerated imaging with both artifact reduction and different contrast mechanisms near metallic implants. Materials and Methods: Slice-encoding for metal artifact correction (SEMAC) is a modified spin echo sequence that uses view-angle tilting and slice-direction phase encoding to correct both in-plane and through-plane artifacts. Standard spin echo trains and short-TI :Inversion recovery (STIR) allow efficient PD-weighted imaging with optional fat suppression. A completely linear reconstruction allows incorporation of parallel imaging and partial Fourier imaging. The signal-to-noise ratio (SNR) effects of all reconstructions were quantified in one subject. Ten subjects with different metallic implants were scanned using SEMAC protocols, all with scan times below 11 minutes, as well as with standard spin echo methods. Results: The SNR using standard acceleration techniques is unaffected by the linear SEMAC reconstruction. In all cases with implants. accelerated SEMAC significantly reduced artifacts compared with standard imaging techniques. with no additional artifacts from acceleration techniques. The use of different contrast mechanisms allowed differentiation of fluid from other structures in several subjects. Conclusion: SEMAC imaging can be combined with standard echo-train imaging, parallel imaging, partial-Fourier imaging. and inversion recovery techniques to offer flexible image contrast with a dramatic reduction of metal-induced artifacts in scan times under 11 minutes.
引用
收藏
页码:987 / 996
页数:10
相关论文
共 31 条
[1]
Beatty PJ., 2007, Proceedings of the 15th Annual Meeting of ISMRM, P1749
[2]
Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods [J].
Brau, Anja C. S. ;
Beatty, Philip J. ;
Skare, Stefan ;
Bammer, Roland .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :382-395
[3]
Reduction of blurring in view angle tilting MRI [J].
Butts, K ;
Pauly, JM ;
Gold, GE .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :418-424
[4]
BYDDER G M, 1985, Magnetic Resonance Imaging, V3, P251, DOI 10.1016/0730-725X(85)90354-6
[5]
A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[6]
TOTAL INHOMOGENEITY CORRECTION INCLUDING CHEMICAL-SHIFTS AND SUSCEPTIBILITY BY VIEW ANGLE TILTING [J].
CHO, ZH ;
KIM, DJ ;
KIM, YK .
MEDICAL PHYSICS, 1988, 15 (01) :7-11
[7]
CHO ZH, 1987, P SMRM 6 ANN M NEW Y, P912
[8]
Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[9]
SPIN ECHOES [J].
HAHN, EL .
PHYSICAL REVIEW, 1950, 80 (04) :580-594
[10]
Hennig J, 2000, MAGNET RESON MED, V44, P983, DOI 10.1002/1522-2594(200012)44:6<983::AID-MRM23>3.0.CO