Carbonate ion-selective electrode with reduced interference from salicylate

被引:22
作者
Bobacka, J
Maj-Zurawska, M
Lewenstam, A [1 ]
机构
[1] Abo Akad Univ, Proc Chem Grp, Ctr Proc Analyt Chem & Sensor Technol ProSens, SF-20500 Turku, Finland
[2] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
[3] Stanislaw Staszic Univ Min & Met, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
blood serum; total carbon dioxide; carbonate ion-selective electrode; salicylate interference; discriminating membrane;
D O I
10.1016/S0956-5663(02)00179-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A carbonate ion-selective electrode for determination of total carbon dioxide species such as carbon dioxide, bicarbonate and carbonate with reduced interference from salicylate is described. Derivatives of trifluoroacetophenone were used as neutral carriers for carbonate. A polymer-free liquid carbonate-selective membrane with a cellophane outer membrane was found to give a carbonate-selective electrode with a negligible response to salicylate. The electrical contact was obtained by insertion of a silver/silver chloride electrode directly into the liquid membrane. The electrode does not require any aqueous filling solution and is therefore maintenance-free. The response to carbon dioxide species was found to be highly reproducible with a response time of 1-2 min at total carbon dioxide concentrations in the range from 5 to 50 mM. The lifetime of the electrode was at least 3 months. The electrode is regarded as very promising for clinical analysis of carbon dioxide species in body fluids such as plasma and serum. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 29 条
[21]  
SCOTT WJ, 1986, CLIN CHEM, V32, P137
[22]   ELECTRODES FOR BLOOD PO2 AND PCO2 DETERMINATION [J].
SEVERINGHAUS, JW ;
BRADLEY, AF .
JOURNAL OF APPLIED PHYSIOLOGY, 1958, 13 (03) :515-520
[23]   Enhanced serum carbon dioxide measurements with a silicone rubber-based carbonate ion-selective electrode and a high-pH dilution buffer [J].
Shin, JH ;
Sakong, DS ;
Nam, HY ;
Cha, GS .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :221-225
[24]   Trifluoroacetophenone derivative-based carbonate ion-selective electrodes: effect of diluent pH on the anion selectivity [J].
Shin, JH ;
Lee, JS ;
Lee, HJ ;
Chu, JH ;
Pyun, HJ ;
Nam, H ;
Cha, GS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 468 (01) :76-84
[25]   A planar pCO2 sensor with enhanced electrochemical properties [J].
Shin, JH ;
Lee, JS ;
Choi, SH ;
Lee, DK ;
Nam, H ;
Cha, GS .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4468-4473
[26]   Observations on the behaviour of some trifluoroacetophenone derivatives as neutral carriers for carbonate ion-selective electrodes [J].
Sokalski, T ;
Paradowski, D ;
Ostaszewska, J ;
MajZurawska, M ;
Mieczkowski, J ;
Lewenstam, A ;
Hulanicki, A .
ANALYST, 1996, 121 (02) :133-138
[27]  
STEELMAN M, 1984, CLIN CHEM, V30, P562
[28]  
TIETZ NW, 1990, CLIN GUIDE LAB TESTS, P746
[29]  
WISE WM, 1973, Patent No. 3723281