Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative

被引:48
作者
Bossuyt, PM [1 ]
Reitsma, JB [1 ]
Bruns, DE [1 ]
Gatsonis, CA [1 ]
Glasziou, PP [1 ]
Irwig, LM [1 ]
Lijmer, JG [1 ]
Moher, D [1 ]
Rennie, D [1 ]
de Vet, HCW [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1100 DE Amsterdam, Netherlands
关键词
D O I
10.2214/ajr.181.1.1810051
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. To improve the accuracy and completeness of reporting of studies of diagnostic accuracy in order to allow readers to assess the potential for bias in a study and to evaluate the generalisability of its results. METHODS. The Standards for Reporting of Diagnostic Accuracy (STARD) steering committee searched the literature to identify publications on the appropriate conduct and reporting of diagnostic studies and extracted potential items into an extensive list. Researchers, editors, and members of professional organisations shortened this list during a 2-day consensus meeting with the goal of developing a checklist and a generic flow diagram for studies of diagnostic accuracy. RESULTS. The search for published guidelines about diagnostic research yielded 33 previously published checklists, from which we extracted a list of 75 potential items. At the consensus meeting, participants shortened the list to a 25-item checklist, by using evidence whenever available. A prototype of a flow diagram provides information about the method of recruitment of patients, the order of test execution and the numbers of patients undergoing the test under evaluation, the reference standard, or both. CONCLUSIONS. Evaluation of research depends on complete and accurate reporting. If medical journals adopt the checklist and the flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 19 条
[1]   Improving the quality of reporting of randomized controlled trials - The CONSORT statement [J].
Begg, C ;
Cho, M ;
Eastwood, S ;
Horton, R ;
Moher, D ;
Olkin, I ;
Pitkin, R ;
Rennie, D ;
Schulz, KF ;
Simel, D ;
Stroup, DF .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (08) :637-639
[2]   BIASES IN THE ASSESSMENT OF DIAGNOSTIC-TESTS [J].
BEGG, CB .
STATISTICS IN MEDICINE, 1987, 6 (04) :411-423
[3]   The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Moher, D ;
Rennie, D ;
de Vet, HCW ;
Lijmer, JG .
CLINICAL CHEMISTRY, 2003, 49 (01) :7-18
[4]   Summary receiver operating characteristic curves as a technique for meta-analysis of the diagnostic performance of duplex ultrasonography in peripheral arterial disease [J].
deVries, SO ;
Hunink, MGM ;
Polak, JF .
ACADEMIC RADIOLOGY, 1996, 3 (04) :361-369
[5]   Value of flow diagrams in reports of randomized controlled trials [J].
Egger, M ;
Jüni, P ;
Bartlett, C .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (15) :1996-1999
[6]   THE EFFICACY OF DIAGNOSTIC-IMAGING [J].
FRYBACK, DG ;
THORNBURY, JR .
MEDICAL DECISION MAKING, 1991, 11 (02) :88-94
[7]  
Griner P F, 1981, Ann Intern Med, V94, P557
[8]  
GUYATT GH, 1986, CAN MED ASSOC J
[9]   DISEASE, LEVEL OF IMPACT, AND QUALITY OF RESEARCH METHODS - 3 DIMENSIONS OF CLINICAL EFFICACY ASSESSMENT APPLIED TO MAGNETIC-RESONANCE-IMAGING [J].
KENT, DL ;
LARSON, EB .
INVESTIGATIVE RADIOLOGY, 1992, 27 (03) :245-254